期刊文献+

一对高亲和力抗人肌钙蛋白I单克隆抗体的制备及鉴定 被引量:2

Preparation and Identification of a Pair of High Affinity Monoclonal Antibody Against Human Cardiac Troponin I
下载PDF
导出
摘要 目的获取抗人肌钙蛋白I(cTnI)的单克隆抗体(McAb)。方法以人cTnI作为抗原,免疫Balb/c小鼠,通过杂交瘤技术制备了抗人cTnI高亲和力、高特异性单克隆抗体。随后采用间接ELISA法测定抗血清效价,用protein G亲和纯化法纯化抗体,抗原竞争ELISA法鉴定抗体亲和力,SDS-PAGE法鉴定纯度,Western blotting鉴定抗cTnI单克隆抗体的特异性,竞争ELISA法分析抗原结合位点。结果筛选出9株稳定分泌抗cTnI的单抗杂交瘤细胞株,其中A3、A9两株免疫球蛋白亚类均为IgG2a,分泌的抗体纯度高,与CK-MB、cTnT无交叉反应,效价均为:1∶1024000,亲和力分别为4.21×108mol/L、1.07×108mol/L,抗原结合位点不同。结论成功制备出了一对高亲和力、高特异性抗人cTnI单克隆抗体。 Objective To prepare monoclonal antibodies against human cardiac troponin Ⅰ(cTnⅠ). Methods Balb/c mice were immunized by human cTnⅠ as the antigen, and the high affinity and specificity monoclonal antibody against human cardiac troponin Ⅰ was prepared through hybridoma technology. The titer of the antiserum,purified by protein G affinity of antibody,was then determined by indirect ELISA. The antigen binding site and the affinity were analyzed by competitive ELISA. SDS-PAGE and Western blotting were used to identify the specificity. Results Total 9 strains of hybridoma cell lines secreting monoclonal antibody against cTnI were obtained,and the antibody secreted by A3, A9 were of high purity and its immunoglobulin subclasses was IgG2a. There was no cross reaction with CK-MB, cTnT. Both titers were 1: 1024000, and the affinity were 4.21 ×10^8mol/L 1.07× 10^8mol/L respectively. The antigen binding sites for them were different. Conclusion A pair of affinity and specificity of monoclonal antibody against human cardiac troponin Ⅰwas prepared successfully. and high
出处 《标记免疫分析与临床》 CAS 2014年第4期462-465,共4页 Labeled Immunoassays and Clinical Medicine
基金 国家高技术研究发展计划(863计划)资助项目(2011AA02A111)
关键词 人肌钙蛋白I 单克隆抗体 亲和力 特异性 Human troponinⅠ Monoclonal antibody Affinity Specificity
  • 相关文献

参考文献8

  • 1Bhavsar P K,Brand N J,Yacoub M H,et al.Isolation and characterization of the human cardiac troponin Ⅰ gene (TNN I3).Genomics,1996,35 (1):11-23.
  • 2Galvani M,Ferrini D,Ghezzi F,et al.Candiac markers and risk stratification:an integrated approach.Clin Chim Acta,2001,311 (1):9-17.
  • 3韩雪松,李强,丛进阳.心肌肌钙蛋白I检测及临床诊断标准化进展[J].中华检验医学杂志,2004,27(3):197-200. 被引量:72
  • 4白丽,Dent,L.应用Protein G纯化细胞培养上清中的大鼠单抗[J].免疫学杂志,1999,15(3):207-209. 被引量:17
  • 5金冬雁 黎孟枫.分子克隆实验指南第2版[M].北京:科学出版社,1998.862-897.
  • 6金建平.单克隆抗体亲和力的测定及其意义.生物工程学报,1987,3(3):169-172.
  • 7Reichlin T,Hochholzer W,Bassetti S,et al.Early diagnosis of myocardial infarction with sensitive cardiac troponin assays.N Engl J Med,2009,361 (9):858-867.
  • 8Morjana N A.Degradation of human cardiac troponin Ⅰ after myocardial infarction.Biotechnol Appl Biochem,1998,28(Pt2):105-111.

二级参考文献10

  • 1JaffeAS,RavkildeJ,RobertsR ,etal.It’stimeforachangetotroponinstandard[].Circulation.2000
  • 2Apple FS.Acute myocardial infarction and coronary reperfusion.Serum cardiac markers for the 1990s[].American Journal of Clinical Pathology.1992
  • 3Cummins B,Auckland ML,Cummins P.Cardiac - specific troponin - Ira dioimmunoassay in the diagnosis of acute myocardial infarction[].American Heart Journal.1987
  • 4Christenson RH,Duh SH,Apple FS,et al.Standardization of cardiac troponin I assays: round Robin of ten candidate reference materials[].Clinical Chemistry.2001
  • 5Reiffert S,Jaquet K,Heilmeyer LM,et al.Stepwise subunit interaction changes by mono- and bisphosphorylation of cardiac troponin I[].Biochemistry.1998
  • 6Morjana NA.Degradation of human cardiac troponin I after myocardial infarction[].Biotechnology and Applied Biochemistry.1998
  • 7Mockel M,Heller GJ,Berg K,et al.The acute coronary syndrome diagnosis and prognostic evaluation by troponin I is influenced by the test system affinity to different troponin complexes[].Clinica Chimica Acta.2000
  • 8Katrukha AG,Bereznikova AV,Pettersson K,et al.Degradation of cardiac troponin I: implication for reliable immunodetection[].Clinical Chemistry.1998
  • 9Shi Q,Ling M,Zhang X,et al.Degradation of cardiac troponin I in serum complicates comparisons of cardiac troponin I assays[].Clinical Chemistry.1999
  • 10Katrukha AG,Bereznikova AV,Filatov V,et al.Biochemical factors influencing measurement of cardiac troponin I in serum[].Clinical Chemistry and Laboratory Medicine.1999

共引文献89

同被引文献20

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部