摘要 某电厂超临界机组循环水泵大轴发生断裂,造成了重大设备事故。对循环水泵大轴断口进行了光谱、硬度和金相检测,依据检测结果,分析了循环水泵大轴发生断裂的原因,提出了预防措施。 A fracture accident occurred to major shaft of the circulating water pump for the super critical unit in a power plant.The fracture of major shaft for the circulating water pump was inspected,through spectral analysis and metallography were hardness test. According to the test results,the causes of c major shaft fracture of the circulating pump were analyzed,and relative precautionary measures were put forward.
出处 《华电技术》 CAS 2014年第8期27-29,33,共4页 HUADIAN TECHNOLOGY
关键词 循环水泵大轴 断裂 检测 原因分析 防护措施 circulating water pump major shaft fracture inspection cause analysis precautionary measures