针对建筑消防设计中的一些常见问题,结合个人工作经验,综合消防意见、审查意见、论坛讨论等,对室外消防给水、消防增压设备、合理布置室内消火栓、室外消防管道以及气体灭火系统等方面作出探讨性的意见及建议,供设计人员参考借鉴,以求消防给水设计的合理性和经济性。
In view of some common problems in the fire protection design of buildings, combined with personal work experience, integrated fire protection advice, review comments, forums etc, to explore the opinions and suggestions with outdoor fire water, Make -up pump, reasonably dispose indoor fire hydrants, outdoor fire fighting pipeline and gas fire extinguishing system, offer a reference for designers, in order to fire water supply design rationality and economy.
出处
《福建建筑》
2014年第9期24-26,共3页
Fujian Architecture & Construction
关键词
室外消防水源
消防增压设备
合理布置室内消火栓
气体灭火系统
Outdoor fire water
Make -up pump
Reasonably dispose indoor fire hydrants