基于瞬时无功功率感应电机转子断条故障诊断研究 被引量:7

Fault diagnosis of broken bar in induction motor based on instantaneous reactive power
下载PDF
导出
摘要 在基于定子电流信号进行异步电机故障诊断时,转子断条故障特征频率分量常常被电流的基频分量淹没。针对这种情况,本文提出一种新型的基于瞬时无功功率的转子断条故障诊断方法。该方法首先对定子电压和电流进行Hilbert变换,然后在此基础上构建瞬时无功功率。通过对无功功率进行频谱分析,选取特征频率2ksf作为转子断条的故障诊断判据。同时定义一个新的故障严重程度系数,对感应电机转子故障严重程度进行判别。实验结果表明该方法能有效进行转子断条故障诊断。与传统的Hilbert模量方法和瞬时功率方法相比,该方法因没有交叉项而频谱简单;只需采集单相电流,不需要进行坐标变换,简化了硬件和软件,节省计算时间。 In traditional method based on the stator current signal of induction motor fault diagnosis,rotor broken bar fault characteristic frequency component was flood by the current fundamental frequency component. In view of this situation,a novel method of broken bar fault diagnosis based on the instantaneous reactive power was proposed. The instantaneous reactive power was defined as the cross product of the voltage,current after Hilbert transform. The characteristic frequency of 2ksf was used as the rotor broken bar fault diagnosis criterion by reactive power spectrum analysis. At the same time,In order to know the induction motor rotor fault severity discrimination,a new fault severity factor was defined. The experimental results showed that this method can effectively diagnose the rotor broken bar fault. The advantages of the method was simple spectrum,and no cross terms; only one current signal was needed,and it doesn't used coordinate transformation,the smaller hardware and software spending compared with the method based on Hilbert or instantaneous power.
出处 《电机与控制学报》 EI CSCD 北大核心 2014年第9期112-116,共5页 Electric Machines and Control
基金 国家高技术研究发展计划项目(2009AA11Z217) 国家自然科学基金(61273158) 湖南教育厅科究项目(11C0725)
关键词 瞬时无功功率 感应电机 转子断条 故障诊断 instantaneous reactive power induction motor rotor broken bar fault diagnosis
  • 相关文献

参考文献15

二级参考文献89

共引文献258

同被引文献87

引证文献7

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部