期刊文献+

Evaluation of 1-kW Class PEM Fuel Cell Stack under In-Situ Conditions Considering Individual Cells 被引量:1

Evaluation of 1-kW Class PEM Fuel Cell Stack under In-Situ Conditions Considering Individual Cells
下载PDF
导出
摘要 Focusing on the stack performance is important for practical use of PEM (proton exchange membrane) fuel cells. This paper describes the experiments and evaluation on the performance of 1-kW class PEM FC (fuel cell) stacks for reliability improvement. We investigated the stack performance, voltage distributions, and internal resistance of the single cells of a PEMFC stack. The standard deviation of individual cell voltages increased almost linearly with the current load by 2.5 times that in the case of an open-circuit voltage, with a standard deviation of 33 A. From the results of the current-interrupt tests, the internal resistance of the FC stack was calculated to be 43.53 mΩ. The internal resistances of each individual cell were not uniform. The average internal resistance was 0.505 mΩ at 18 A, which was less than that calculated from the stack current-interrupt test. We also investigated the current distribution in the PEM FC stack under in-situ conditions using a triaxial magnetic sensor probe. From the results, the current distribution tended to concentrate on the underside of the cell. Each I-V curve at the divided plane can be obtained using the developed method.
出处 《Journal of Energy and Power Engineering》 2014年第9期1543-1551,共9页 能源与动力工程(美国大卫英文)
关键词 Proton exchange membrane fuel cell PEM STACK current distribution magnetic field magnetic sensor probe diagnostics. 质子交换膜燃料电池 单个细胞 千瓦级 评估 PEMFC 电堆 电流负载 标准偏差
  • 相关文献

参考文献13

  • 1Feitelberg, A. S., Stathopoulos, J., Qi, Z., Smith, C., and Elter, J. F. 2005. "Reliability of Plug Power GenSys Fuel Cell Systems." Journal of Power Sources 147: 203-7.
  • 2Maekawa, A. and Aoki, T. 2006. "PEM FC Stack Field Experiences." ESC Transactions 1 (8): 385-400.
  • 3Jang, J. H., Chieh, H. C., Yan, W. M., and Sun, W. L. 2008. "Effects of Operating Conditions on the Performances of Individual Cell and Stack of PEM Fuel Cell." Journal of Power Sources 180 (1): 476-83.
  • 4Zhu, W. H., Payne, R. U., Cahela, D. R., and Tatarchuk, B J. 2004."1' Uniformity Analysis at MEA and Stack Levels for a Nexa PEM Fuel Cell System." Journal of Power Sources 128 (2): 231-8.
  • 5Lin, H., Cao, T. F., Li, C., He, Y. L., and Tao, W. Q. 2012. "In Situ Measurement of Temperature Distribution within a Single Polymer Electrolyte Membrane Fuel Cell." International Journal of Hydrogen Energy 37 (16):11871-86.
  • 6Lee, C. Y., Weng, F., Cheng, C. K., Chang, C. P. 2012. "In situ Monitoring of High-Temperature Proton Exchange Membrane Fuel Cell Stack Using Flexible Micro Temperature and Voltage Sensors." Journal of Power Sources 205 (1): 345-9.
  • 7Ghosh, P. C., Wuster, T., Dohle, H., Kimiaie, N., Mergel, J., and Stolten, D. 2006. "In Situ Approach for Current Distribution Measurement in Fuel Cells." Journal of Power Sources 154 (1): 184-91.
  • 8Sasabe, T., Tsushima, S., and Hirai, S. 2010. "In-Situ Visualization of Liquid Water in an Operating PEMFC by Soft X-ray Radiography." International Journal of Hydrogen Energy 35 (20): 11119-28.
  • 9Tsushima, S., Ikeda, T., Koido, T., and Hirai, S. 2010. "Investigation of Water Distribution in a Membrane in an Operating PEMFC by Environmental MRI: I. Effects of Operating Conditions." Journal of Electrochemical Society 157 (12): B1814-8.
  • 10Hauer, K. H., Potthast, R., Wuster, T., and Stolten, D. 2005. "Magnetotomography--A New Method for Analysing Fuel Cell Performance and Quality." Journal of Power Sources 143 (1-2): 67-74.

同被引文献1

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部