期刊文献+

同位镀锑膜示差脉冲溶出伏安法测定水中痕量铅 被引量:2

In-situ Plating Antimony Film Electrode for Determination of Trace Leads by Differential Pulse Voltammetry
下载PDF
导出
摘要 本文研究示差脉冲伏安分析法测定溶液中痕量重金属铅离子。以同位镀锑膜电极作为工作电极,0.5moL/LKCI溶液作为支持电解质,铅离子的溶出峰在-0.47V,富积时间为110s,在(0~80)μg/L浓度范围内蜂电流与铅离子浓度呈线性关系,对于溶液中铅离子的检测限达到0.06μg/L。同位镀锑电极具有廉价、低毒性、高灵敏和稳定性好的特点,可以用于环境水样中重金属离子的实时分析检测。 Differential pulse voltammetry was proposed for determination of trace leads by using an in-situ plating antimony film electrode as a working electrode. The experiment conditions for determination of lead in the water were optimized. In 0.5 mol/ L KC1 solution, the sensitive potentiometric stripping peaks of lead ions were obtained as 4). 47 V. With the deposition time of 110 s, the stripping peak value changed linearly with the lead ion concentrations in the range of 0 ~80 μg/L. The detection limit of Pb2 + was 0.06 μg/L. The in-situ plating antimony film electrode possesses low cost, stability, low toxicity and sensitivity, which make it hopeful candidate for in-situ water monitoring for heavy metals.
出处 《安庆师范学院学报(自然科学版)》 2014年第3期102-105,共4页 Journal of Anqing Teachers College(Natural Science Edition)
关键词 电化学 同位镀锑 膜电极 示差脉冲伏安法 electrochemistry, in-situ plating antimony, film electrode, differential pulse voltammeters, leads
  • 相关文献

参考文献14

二级参考文献135

共引文献16

同被引文献56

  • 1Sanna Q,Pilo MI,Piua RC,et a L.Determination of heavy metals in honey by anodic stripping voltammetry at microelectrodes[J].Anal Chim Acta,2000,415(1-):165-173.
  • 2Du XY,Gong WL,Zhang YX,et al.Preparation of bismuth film-modified gold electrodes for the determination of trace level of heavy metals in vegetables[J].Sensor Lett,2007,22(5):572-577.
  • 3Hocevar SB,Svancara I,Ogorevc B,et al.Antimony Film Electrode for Electrochemical Stripping Analysis[J].Anal Chem,2007(79):8639-8643.
  • 4Bobrowski A,Putek M,Zarebski J.Antimony film electrode prepared in situ in hydrogen potassium tartrate in anodic stripping voltammetric trace detection of Cd(11),Pb(11),Zn(11),Tl(I),In(III)and Cu(11)[J].Electroanalysis,2012,24(5):1071-1078.
  • 5Jovanovski V,Hocevar SB,Ogorevc B.Ex situ prepared antimony film electrode for electrochemical stripping measurement of heavy metal ions[J].Electroanalysis,2009,21(21):2321-2324.
  • 6Hocoeevar SB,Ogorevc B,Wang J,et a L.A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry[J].Electroanalysis,2002,24(14):1707-1712.
  • 7Slavec M,Hocevar S B,Baldrianova L,et a L.Antimony film microelectrode for anodic stripping measurement of Cadmium(11),Lead(11)and Copper(11)[J].Electroanalysis,2010,22(14):1617-1622.
  • 8Yi WJ,Li Y,Ran G,et a L.Determination of cadmium(11)by square wave anodic stripping voltammetry using bismuth-antimony film electrode[J].Sensors and Actuators B,2012(166-167):544-548.
  • 9Borgo SD,Jovanovski V,Hocevar SB.Antimony film electrode for stripping voltammetric measurement of Hg(11)in the presence of Cu(11)[J].Electrochimica Acta,2013(88):713-717.
  • 10Kokkinos C,Economou A,Raptis I,et al.Novel disposable microfabricated antimony-film electrodes for adsorptive stripping analysis of trace Ni(11)[J].Electrochemistry Communications,2009,11(2):250-253.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部