针对武汉地区某办公建筑,利用DeST软件计算其全年逐时负荷。利用TRNSYS软件对该建筑分别建立常规地源热泵系统(GSHP)模型与冷却塔复合地源热泵系统(HGSHP)模型,通过模拟发现冷却塔复合地源热泵系统更利于土壤的热平衡,且机组和系统全年的COP也较高。
The building load of a certain office building was calculated by DeST. A ground source heat pump model(GSHP)and a ground source heat pump system aided by cooling tower model(HGSHP) were established by TRNSYS. Comparison of the simulation results using TRNSYS indicatedthat the ground source heat pump system aided by cooling tower model was better at the heat balance of the soil and could provide high COP of heat pump unit and the system.
出处
《洁净与空调技术》
2014年第3期16-19,共4页
Contamination Control & Air-Conditioning Technology
关键词
常规地源热泵
冷却塔复合地源热泵系统
土壤热平衡
COP
Ground source heat pump
Ground source heat pump system aided by cooling tower
Heat balance of the soil