摘要
针对双区静电空气净化器,通过实验测试,研究了外加高压静电电压、电场截面风速对不同粒径微粒的计数效率的影响,并分析了不同截面风速下双区静电净化器的伏-安特性关系,给出静电模块配备高压静电的建议。
For dual-stage electrostatic air cleans tested by experiment to study the impact of the high-voltage electrostatic and airflow speed on the counting efficiency of different cross-sectional diameter of particles, and analyze the I-V characteristic of dualstage electrostatic cleans on different airflow speed. Giving the suggest electrostatic module is equipped with high-pressure static electricity.
出处
《洁净与空调技术》
2014年第3期33-35,共3页
Contamination Control & Air-Conditioning Technology
关键词
双区静电空气净化器
静电电压
截面风速
计数效率
伏-安特性
Double-stage electrostatic air cleans
Electrostatic voltage
Airflow speed
Counting efficiency
I-V characteristic