摘要
红外测温能在不接触、不停电情况下探明设备的发热程度,是当前变电运维工作中必不可少的技术手段。本文从红外测温的原理出发,阐述了该项技术在状态检修、故障处理中的应用情况,并给出具体实例,最后就红外测温的注意事项作归纳,以期更好地推广该项技术。
The infrared temperature measurement can ascertain the heat of the equipment under the situation of no touch and non-power cut, which is the essential technology in current substation operations. From the principle of infrared temperature measurement, this paper elaborates its situation in condition-based maintenance and fault processing, and gives the specific example. Finally the paper summarizes the dos and don'ts of the infrared temperature measurement to better popularize this technology.
出处
《科技广场》
2014年第8期65-68,共4页
Science Mosaic
关键词
变电运维
红外测温
应用
Substation Operation and Maintenance
Infrared Temperature Measurement
Application