摘要
叙述了无弧分合闸方案,分析了合闸过程方案及分闸过程方案,指出零电流分断控制技术存在的问题,并提出了一种具有明显分断口的无弧交流接触器结构,其大大提高了接触器的电寿命,可靠地实现了电气隔离。
Describes an arcless switching program, analyzes the program of closing process and program of opening process, points out the problems of zero-current breaking control technology, and proposes a kind of structure of arcless AC contactor with obvious breaking points, which improves the electrical life of contactor greatly, and realizes electrical isolation reliably.
出处
《能源与节能》
2014年第10期31-32,47,共3页
Energy and Energy Conservation
关键词
交流接触器
电寿命
无弧通断
分断口
AC contactor
electrical life
arcless switching
breaking points