期刊文献+

3D影像导航辅助经皮骶髂螺钉置入治疗骨盆后环损伤 被引量:1

Accessorial effect of 3D-fluoroscopic navigated percutaneous screw fixation in the treatment of posterior pelvic ring injuries
原文传递
导出
摘要 【目的】评价3D影像导航辅助经皮骶髂螺钉置入治疗骨盆后环损伤的安全性和治疗效果。【方法】回顾我院骨科2009年3月-2012年12月采取3D影像导航辅助经皮置入骶髂螺钉治疗骨盆后环损伤患者18例,平均年龄40.2岁(23~61岁);交通伤12例,坠落伤5例,房屋倒塌砸伤1例。根据AO骨折分型:B 1.2型3例,B 2.2 2例,C1.2型7例,C1.3型5例,C 2.3 1例。【结果】术中共计置入骶髂螺钉40枚,每枚螺钉置入平均耗时(29.12±3.00)min,每枚螺钉术中平均透视(4.55±0.80)min。所有螺钉置入位置均较为满意,无伤口感染发生,所有患者术后均未出现明显神经系统并发症。采用Matta标准评价骨折复位情况:优12例,良5例,可1例。采用Maieed评估体系进行术后功能评价:优11例,良7例。【结论】研究显示3D影像导航辅助经皮骶髂螺钉置入技术是一种治疗骨盆后环损伤的有效方法。 【Objective】To evaluate the security and effect of 3D-fluoroscopic navigated percutaneous screw fixation in the treatment of posterior pelvic ring injuries.【MGthods】 18 patients(from March 2009 to December 2012) with posterior pelvic ring injuries were treated with 3D-fluoroscopic navigation.There were 13 males and 5 females with an average age of 40.2 years(ranged from 23 to 61years).12 cases were caused by traffic accidents,5 cases by high fall,and1 case by collapsed building.Based on AO classification,there were 3 cases of B 1.2 type,2 cases of B2.2 type,7 cases of C1.2 type,5 cases of CL3 type,and 1 cases of C2.3 type.The perioperative data and radiographic outcomes of the patients were collected and analyzed.【 Results】 A total of 40 iliosacral screws were inserted.The mine time of navigated sacroiliac screw was(29.12 ± 3.00) min.The mine time of intra-operative fluoroscopy was(4.55 ± 0.80) min.No screw misplacement was observed in intraoperative fluoroscopic control images.No wound infection or iatrogenic neurovascular damage was observed.The following results were obtained with respect to the Matta score:12 X excellent,5 × good results,1 × fair result.According to Majeed functional scoring,the results were excellent in 11 cases and good in 7 cases.【Conclusion 】 Our results showed that 3D-fluoroscopic navigation technique for the pelvic ring injuries could become a safe and effective alterative method for the treatment of pelvic ring injuries.
出处 《武警后勤学院学报(医学版)》 CAS 2014年第6期484-487,F0003,共5页 Journal of Logistics University of PAP(Medical Sciences)
关键词 骨盆骨折 透视导航 经皮内固定 骶髂螺钉 Pelvic fractures Fluoroscopic-navigation Percutaneous fixation Iliosacral screws
  • 相关文献

参考文献13

  • 1Tabaie SA, Bledsoe JG, Moed BR. Biomechanical Comparison of Standard Iliosacral Screw Fixation to Transsacral Locked Screw Fixation in a Type C - Zone II Pelvic Fracture Model [J]. J Orthop Trauma, 2013, 27(9):521-526.
  • 2Zwingmann J, Konrad G, Mehlhorn A T, et al. Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional) [J]. J Trauma, 2010, 69(6): 1501-1506.
  • 3Zwingmann J, Konrad G, Koner E, et al. Computer-navigated iliosacral screw insertion reduces malposition rate and radia- tion exposure [J]. Clin Orthop Relat Res, 2009, 467(7):1833- 1838.
  • 4梁国穗,邓宁,张戈,吕红斌.骨盆-髋臼骨折X线透视导航下闭合复位与经皮固定[J].中华创伤骨科杂志,2005,7(7):637-639. 被引量:24
  • 5罗从风,胡承方,周凯华,曾炳芳.透视导航下骶髂关节螺钉固定治疗骨盆后环骨折[J].中华创伤杂志,2008,24(1):5-9. 被引量:14
  • 6Matta JM, Tornetta P, 3rd. Internal fixation of unstable pelvic ring injuries [J]. Clin Orthop Relat Res, 1996(329):129-140.
  • 7Majeed SA. Grading the outcome of pelvic fractures [J]. J Bone Joint Surg Br, 1989, 71(2):304-306.
  • 8Hinsche AF, Giannoudis PV, Smith RM. Fluoroscopy-based mulfiplanar image guidance for insertion of sacroiliac screws [J]. Clin Orthop Relat Res, 2002, (395):135-144.
  • 9Stockle U, Schaser K, Konig B. Image guidance in pelvic and aeetabular surgery-expectations, success and limitations [J]. Injury, 2007, 38(4):450-462.
  • 10Zwingmann J, Hauschild O, Bode G, et a/. Malposition and revision rates of different imaging modalities for percutane- ous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis[J]. Arch Orthop Trauma Surg, 2013, 133(9):1257-1265.

二级参考文献21

  • 1孔建中,郭晓山,潘骏,黄俊武,杨雷,彭茂修,陈龙,翁益民.经皮骶髂关节螺钉治疗骶骨纵形骨折[J].中华创伤杂志,2005,21(6):410-412. 被引量:39
  • 2Matta JM, Tornetta III P. Internal fixation of unstable pelvic ring injuries. Clin Orthop, 1996, (329) :129 - 140.
  • 3Routt ML, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. Clin Orthop, 2000, (375) : 15 - 29.
  • 4Gorczyca JT, Varga E, Woodside T, et al. The strength of iliosacral lag screws in transiliac bars in the fixation of vertically unstable pelvic injuries with sacral fractures. Injury, 1996, 27 (8) :561-564.
  • 5Yinger K, Scalise J, Olson SA, et al. Biomechanical comparison of posterior pelvic ring fixation. J Orthop Trauma, 2003, 17 (7) : 481 - 487.
  • 6Routt ML Jr, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma, 1997, 11(8):584-589.
  • 7Templeman D, Schmidt A, Freese J, et al. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop, 1996, (329) :194 - 198.
  • 8Sanders R, Koval K J, DiPaquale T, et al. Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg (Am), 1993, 75 (3) :326 -330.
  • 9Barei DP, Bellabarba C, Mills W J, et al. Percutaneous management of unstable pelvic ring disruptions. Injury, 2001, 32( Suppl 1 ) :SA33 -44.
  • 10Peters P, Langlotz F, Nolte LP. Computer assisted screw insertion into real 3D rapid prototyping pelvis models. Clin Biomech, 2002, 17 ( 5 ) :376 - 382.

共引文献32

同被引文献7

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部