期刊文献+

丹东变电井水位数据动态分析 被引量:1

DYNAMIC ANALYSIS OF THE WATER LEVEL OF THE POWER SUBSTATION WELL IN DANDONG
下载PDF
导出
摘要 本文主要研究丹东变电井地下流体水位数字化改造后的十五数字资料,对变电井水位的正常动态、干扰动态、同震异常进行全面的分析和总结,识别水位变化中的正常动态和干扰动态,分析干扰动态原因及解决办法,总结典型同震异常特点,以提高利用地下流体观测地震的监测效能。 This paper mainly studies underground fluid level digital data after The tenth five year digital reconstruction of Dandong Biandian well. The normal dynamic, interference dynamic and coseismic anomalies of Biandian water level were comprehensively analyzed and summarized. Recognize The normal dynamics and disturbances dynamic of water level change. Analyse interference dynamic causes and solutions, summarizes the typical characteristics of coseismic anomalies. To improve the utilization efficiency of the earthquake monitoring of underground fluid observation.
机构地区 丹东地震台
出处 《防灾减灾学报》 2014年第3期34-40,共7页 Journal of Disaster Prevention And Reduction
关键词 水位 数字化资料 正常动态 干扰异常 同震异常 water level digital data normal dynamic interference dynamic coseismic anomalies