摘要 随着多层螺旋CT的不断发展,CT冠状动脉成像(CTCA)已成为临床诊断冠心病首选的非侵袭性检查方法。随着患者对降低辐射剂量的要求越来越高,如何在满足诊断质量的成像基础之上,尽量降低辐射剂量,已成为CTCA研究的重点和难点。本研究旨在探讨低管电压设置对256层CT前瞻性心电门控冠状动脉成像的质量影响,以进一步降低辐射剂量。
作者 吴咏梅
出处 《山西医药杂志》 CAS 2014年第17期2018-2019,共2页 Shanxi Medical Journal
  • 相关文献

参考文献7

  • 1Wink O,Hecht HS,Ruijters D.Coronary computed tomographic angiography in the cardiac catheterization laboratory:current applications and future developments[J].Cardiol Clin,2009,27(3):513-529.
  • 2覃杰,董云旭,孟晓春,郭宁,古会珍,钱孝贤,朱康顺,单鸿.320排CT冠状动脉成像低剂量技术的临床应用价值[J].中山大学学报(医学科学版),2010,31(3):436-439. 被引量:9
  • 3Al Moudi M,Sun Z,Lenzo N.Diagnostic value of SPECT,PET and PET/CT in the diagnosis of coronary artery disease:a systematic review[J].Biomed Imaging Interv J,2011,7(2):e9.
  • 4Dill T,Deetjen A,Ekinci O,et al.Radiation dose exposure in multislice computed tomography of the coronaries in comparison with conventional coronary angiography[J].Int J Cardiol,2008,124(3):307-311.
  • 5Triq AH,Shawn DT,Mani V,et al.Low radiation dose ECGgated chest CT angiography on a 256slice multi-detector CT scanner[J].Int J Cardiovasc Imaging,2009,25(2):267-278.
  • 6毕涛,徐磊,张兆琪,杨琳,赵蕾,吕滨,韩丹,柳澄,段青.双源CT前瞻性心电门控序列扫描冠状动脉成像准确性的多中心研究[J].中华放射学杂志,2009,43(7):708-713. 被引量:19
  • 7Wm GW,Mark EO,Matthew JW.Low dose prospectively gated 256slice coronary computed tomographic angiography[J].Int Cardiovasc Imaging,2009,25(2):217-230.

二级参考文献24

  • 1张兆琪,马晓海.64层螺旋CT冠状动脉成像——无创性冠状动脉检查的新纪元[J].中华放射学杂志,2006,40(8):789-791. 被引量:88
  • 2孟冷,张兆琪,吕飙.64层螺旋CT在冠状动脉疾病诊断中的价值[J].中华放射学杂志,2006,40(8):792-796. 被引量:129
  • 3Leschka S,Alkadhi H,Plass A,et al.Accuracy of MSCT coronary angiography with 64-slicetechnology:first experience.Eur Heart J,2005,26:1482-1487.
  • 4Mullet NR,Cademartiri F,van Mieghem CA,et al.Highresolution spiral computed tomographycoronary angiography in patients referred for diagnostic conventional coronaryangiography.Circulation,2005,112:2318-2323.
  • 5Scheffel H,Alkadhi H,Plass A,et al.Accuracy of dual-source CT coronaryangiography:first experience in a high pre-test probability population without heart ratecontrol.Eur Radiol,2006,16:2739-2747.
  • 6Leber AW,Johnson T,Becket A,et al.Diagnostic accuracy of dual-source multi-sliceCT-coronary angiography in patients withan intermediate pretest likelihood for coronaryartery disease.EurHeart J,2007,28:2354-2360.
  • 7Alkadhi H,Scheffel H,Desbiolles L,et al.Dual-source computed tomography coronaryangiography:influence of obesity,calcium load,and heart rate on diagnostic accuracy.EurHeart J,2008,29:766-776.
  • 8Dill T,Deetjen A,Ekinci O,et al.Radiation dose exposure in multislice computedtomography of the coronaries in comparison with conventional coronary angiography.Int JCardiol,2008,124:307-311.
  • 9Einstein AJ,Henzlova MJ,Rajagopalan S.Estimating risk of cancer associated withradiation exposure from 64-slice computed tomography coronaryangiography.JAMA,2007,298:317-323.
  • 10Leschka S,Scheffel H,Desbiolles L,et al.Image quality and reconstruction intervals ofdual-source CT coronary angiography:recommendations for ECG-pulsing windowing.InvestRadiol,2007,42:543-549.

共引文献26

同被引文献13

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部