期刊文献+

一种利用手指图像测量人体心率的方法 被引量:5

Measurement of human heart rate using finger pictures
下载PDF
导出
摘要 在智能手机上,仅利用手机摄像头采集手指颜色的变化图像,实现人体心率的测量.采用图像频谱分割法对采集的手指图像进行滤波,结合3种像素包含的信息及包含的信息的差异性,利用3种像素功率密度谱加权计算出光电容积脉搏波.通过相隔点检测波峰法检测光电容积脉搏波信号,测出人体心率.将测量结果与标准仪器测量结果进行对比,平均误差为1.82%,与真实值的相关系数大于90%,证明了从手指图像测量出人体心率参数的可靠性.将该测量方法应用到手机上,能极大地方便慢性病人对自己健康状态的监控. On the smart phone,a phone camera is used to capture finger images to achieve heart rate measurements.First,we apply the spectrum division method to filter the collected finger images,and then use the weighted power density spectrum of the three pixel to calculate the PPG(PhotoPlethysmoGraphy), based on the information and its differences contained in the three pixels.Then we apply the peak detection method based on the detection of the separated PPG signal to measure the heart rate.Comparing the measured results and the standard results,the average error is 1.82%,and the correlation of the true value is greater than 90%,indicating the reliability of heart rate measurement on finger images.The application of the method can greatly facilitate the convenience of chronic disease monitoring.
出处 《西安电子科技大学学报》 EI CAS CSCD 北大核心 2014年第5期91-97,共7页 Journal of Xidian University
基金 国家自然基金委员会-广东联合基金重点基金资助项目(U1135002) 国家科技部重大专项资助项目(2011ZX03005-002) 陕西省自然科学基础研究计划资助项目(2013JQ8036) 中央高校基本科研业务费资助项目(JY10000903001 JB140309) 长江学者和创新团队发展计划资助项目(IRT1078) 大学生创新性训练计划资助项目(201210701058) 国家自然科学基金资助项目(61303033)
关键词 数字图像处理 光电容积脉搏波 图像频谱分割 智能手机 心率 digital image processing photo plethysmo graphy image spectrum segmentation smartphone heart rate
  • 相关文献

参考文献14

  • 1马俊领,王成,李章俊,赵宏垚.基于PPG的心率和呼吸频率的测量研究[J].光学技术,2011,37(3):309-312. 被引量:27
  • 2Pelegris P, Banitsas K, Orbach T, et al. A Novel Method to Detect Heart Beat Rate Using a Mobile Phone [C]//Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Piscataway: IEEE, 2010: 5488-5491.
  • 3Scully C G, Lee J, Meyer J, et al. Physiological Parameter Monitoring from Optical Recordings with a Mobile Phone [J]. IEEE Transactions on Biomedical Engineering, 2012, 59(2) : 303-306.
  • 4Lamonaca F, Kurylyak Y, Grimaldi D, et al. Reliable Pulse Rate Evaluation by Smartphone [C]//IEEE International Symposium on Medical Measurements and Applications Proceedings. Piscataway: IEEE, 2012: 234-237.
  • 5Fleming S G, Tarassenko L. A Comparison of Signal Processing Techniques for the Extraction of Breathing Rate from the Photoplethysmogram [J]. International Journal of Biological Sciences, 2007, 2(4) : 232-236.
  • 6Millasseau S C, Ritter J M, Takazawa K, et al. Contour Analysis of the Photoplethysmographic Pulse Measured at the Finger [J]. Journal of Hypertension, 2006, 24(8) : 1449-1456.
  • 7Nijboer J, Dorlas J, Mahieu H. Photoelectric Plethysmography: Some fundamental Aspects of the retlection and Transmission Method [J]. Clinical Physics and Physiological Measurement, 1981, 2(3) : 205-215.
  • 8Comtois G, Salisbury J I, Sun Y. A Smartphone-based Platform for Analyzing Physiological Audio Signals [C]//38th Annual Northeast Bioengineering Conference. Piscataway: IEEE, 2012: 69-70.
  • 9Humphreys K G. An Investigation of Remote Non-contact Photoplethysmography and Pulse Oximetry [D]. Maynooth: National University of Ireland, 2007.
  • 10Kurylyak Y, Lamonaca F, Grimaldi D. Smartphone-Based Photoplethysmogram Measurement [M]. Aalborg: River Publishers, 2012: 135.

二级参考文献18

  • 1Nijboer J A, Dorlas J C, Mahieu H F. Photoelectric plethysmography-some fundamental aspects of the reflection and transmis sion methods[J]. Clinical Physics and Physiological Measurement, 1981, 2: 205--215.
  • 2Bernardi L. , Radaelli A. , Solda' P L. Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves[J].Clinic Science, 1996, 90:345-355.
  • 3Anders Johansson, Per Ake Oberg, Gunnar Sedin. Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique[J].Journal of Clinical Moni toring and Computing, 1999,15 : 461-467.
  • 4Nilsson L, Johansson A, Kalman S. Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique[J]. Journal of Clinical Monitoring and Computing, 2000,16: 309-315.
  • 5Nilsson L, Johansson A, Kalman S. Respiration can be moni tored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory mode[J].Acta Anaesthesiologiea Scandinavica, 2005,49(8) : 1157 - 1162.
  • 6Nilsson L, Goscinski T, Johansson A. Age and gender do not influence the ability to detect respiration by photoplethysmography[J].Journal of Clinical Monitoring and Computing, 2006, 20(6) :431--436.
  • 7Clifton D, Douglas J G, Addison P S. Measurement of respiratory rate from the photoplethysmogram in chest clinic patients [J]. Journal of Clinical Monitoring and Computing, 2007, 21 (1) : 55--61.
  • 8Lin Y D, Liu W T, Tsai C C. Coherence Analysis between Respiration and PPG Signal by Bivariate AR Model [J]. Engineering and Technology, 2009, 53 : 847--852.
  • 9Fleming S G, Tarassenko L. A comparison of signal processing techniques for the extraction of breathing rate from the photoplethysmogram[J]. International Journal of Biomedical Sciences, 2007, 2(4): 232--236.
  • 10周衍椒 张锦如.生理学[M].北京:人民卫生出版社,1983.10.

共引文献29

同被引文献19

引证文献5

二级引证文献20

相关作者