Investigation on the relationship between overpressure and sub-harmonic response from encapsulated microbubbles 被引量:2

Investigation on the relationship between overpressure and sub-harmonic response from encapsulated microbubbles
下载PDF
导出
摘要 Sub-harmonic component generated from microbubbles is proven to be potentially used in noninvasive blood pressure measurement. Both theoretical and experimental studies are performed in the present work to investigate the dependence of the sub-harmonic generation on the overpressure with different excitation pressure amplitudes and pulse lengths. With 4-MHz ultrasound excitation at an applied acoustic pressure amplitude of 0.24 MPa, the measured sub-harmonic amplitude exhibits a decreasing change as overpressure increases; while non-monotonic change is observed for the applied acoustic pressures of 0.36 MPa and 0.48 MPa, and the peak position in the curve of the sub-harmonic response versus the overpres- sure shifts toward higher overpressure as the excitation pressure amplitude increases. Furthermore, the exciting pulse with long duration could lead to a better sensitivity of the sub-harmonic response to overpressure. The measured results are ex- plained by the numerical simulations based on the Marmottant model. The numerical simulations qualitatively accord with the measured results. This work might provide a preliminary proof for the optimization of the noninvasive blood pressure measurement through using sub-harmonic generation from microbubbles. Sub-harmonic component generated from microbubbles is proven to be potentially used in noninvasive blood pressure measurement. Both theoretical and experimental studies are performed in the present work to investigate the dependence of the sub-harmonic generation on the overpressure with different excitation pressure amplitudes and pulse lengths. With 4-MHz ultrasound excitation at an applied acoustic pressure amplitude of 0.24 MPa, the measured sub-harmonic amplitude exhibits a decreasing change as overpressure increases; while non-monotonic change is observed for the applied acoustic pressures of 0.36 MPa and 0.48 MPa, and the peak position in the curve of the sub-harmonic response versus the overpres- sure shifts toward higher overpressure as the excitation pressure amplitude increases. Furthermore, the exciting pulse with long duration could lead to a better sensitivity of the sub-harmonic response to overpressure. The measured results are ex- plained by the numerical simulations based on the Marmottant model. The numerical simulations qualitatively accord with the measured results. This work might provide a preliminary proof for the optimization of the noninvasive blood pressure measurement through using sub-harmonic generation from microbubbles.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期268-274,共7页 中国物理B(英文版)
基金 Project supported by the National Basic Research Program from Ministry of Science and Technology,China(Grant No.2011CB707900) the National Natural Science Foundation of China(Grant Nos.81271589,81227004,11174141,11374155,11612032,and 81301616) the Natural Science Foundation of Jiangsu Province,China(Grant Nos.BE2011110 and BK20131017)
关键词 MICROBUBBLE OVERPRESSURE sub-harmonic response blood pressure measurement microbubble, overpressure, sub-harmonic response, blood pressure measurement
  • 相关文献

参考文献19

  • 1Benisty J I 2002 Circulation 106192.
  • 2ZbangCB, LiuZ, GuoXS and Zhang D 2010 Chin. Phys. B20024301.
  • 3Huang B, Zhang Y L, Zhang D and Gong X F 2010 Chin. Phys. B 19 054302.
  • 4de Jong N, Comer R and Lance C T 1994 Ultrasonics 32 447.
  • 5Shi W T and Forsberg F 2000 Ultrasound Med. BioI. 26 93.
  • 6Fairbank W M and Scully M 01977 IEEE Trans. Biomed. Eng. 24 107.
  • 7Bouakaz A, Frinking P J A, de Jong N and Born N 1999 Ultrasound Med. BioI. 25 1407.
  • 8Forsberg F, Liu J B, Shi W T, Furuse J, Shimizu M and Goldberg B B 2005 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 52 581.
  • 9Shi W T, Forsberg F, Raichlen J S, Needleman L and Goldberg B B 1999 Ultrasound Med. Bioi. 25 275.
  • 10Leodore L M, Forsberg F and Shi W T 2007 IEEE International Ultrasonics Symposium Proceedings, P5B-6.

同被引文献6

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部