期刊文献+

58副磁性附着体义齿常见问题的临床研究 被引量:4

The clinical research of the common complication of 58 magnetic- attachment dentures
下载PDF
导出
摘要 目的:观察磁性附着体在口腔义齿修复中出现的并发症,探讨相应的处理方法。方法:对53例患者,58副义齿,123个磁性附着体随访2-6年,平均3年。结果:基托折断8件,衔铁松脱6个,衔铁磨损4个,磁铁松脱5个,基牙龈炎24个,基牙松动拔除7个,牙根折裂1个。结论:磁性附着体能提高可摘义齿的固位力,出现的问题都可以通过选择合适的适应证、正确的操作、修复后定期随访进行预防和处理。 Objective: To find out the complications and solutions of the magnetic attachments used in oral denture prostheses. Methods: 58 dentures were made with 123 magnetic attachments in 53 patients, which were followed up for 2~6 years, an average of 3 years. Results:8 dentures out of the 58 were fractured. Among the 123 keepers,6 were loose or fell off ,4 were abraded clearly. For the magnets, 5 of which were found to be loose or fell out. Signs of gingivitis were found in 24 of the 123 abutments. 7 roots were pulled out because of looseness, and another root was found fractured. Conclusion:Magnetic attachments can improve the retention force of the dentures. And the complications can be prevented or solved by appropriate selection of the candidates, correct operation, and regular follow-up during function.
出处 《中华老年口腔医学杂志》 2014年第4期223-226,共4页 Chinese Journal of Geriatric Dentistry
关键词 磁性附着体 义齿 并发症 magnetic attachments dentures complications
  • 相关文献

参考文献9

二级参考文献18

  • 1魏斌,钱琼,张富强.磁性附着体义齿衔铁的设计[J].上海第二医科大学学报,2004,24(12):1042-1044. 被引量:2
  • 2Kokubo Y, Fukushima S. Magnetic attachment for esthetic management of an overdenture[J]. J Prosthet Dent. 2002,88(3):354-355.
  • 3Hirofumi Kido, Shin-ich Masumi,Masahiro Arita,et al.A Statistical Study of the Clinical Applications of the Magfit 600DentalMagneticAttachment [J]. J Mag Dent, 1994, 3 (1): 44~52
  • 4Yoshinori Nakamura, Yoshinobu Tanaka,Takahashi I,et al.Experimental research on retention of magnetic assemblies to denture bases [J]. J Mag Dent, 1998, 7 (1): 52~58
  • 5Nadeau J. Maxillofacial prosthesis with magnetic stabilizers. J Prosthet Dent,1956, 6 (1) :114
  • 6Robinson JE. Magnets for the retention of a sectional intraoral prosthesis. A case history. J Prosthet Dent,1963,13 (6) :1167-71
  • 7Jackson TR, Healey KW. Rare earth magnetic attachments-the state of the art in removable prosthodontics. Quintessence Int,1987,18 (1) :41- 51
  • 8Gillings BR. Magnetic retention for complete and partial overdentures-Part 1.J Prosthet Dent,1981,4 (5) :484-491
  • 9Stewart BL, Edwards AO. Retention and wear of precision-type attachments. J Prosthet Dent,1983,49 (1) :28-34
  • 10Fhjimoto T, Niimi A, Murakami I, et al. Use of new magnetic attachment for implant-supported overdentures. J Oral Implanto,1998,24 (3) :147-151