摘要 目的比较酸消解法和干灰化法两种前处理法对ICP-MS技术检测调味粉中镉含量的影响,为合理选择ICP-MS技术测定食品样品中镉的前处理方法提供参考。方法分别采用湿法酸消解法和干灰化法处理调味粉质控样品,并用ICP-MS法测定其中的镉含量,通过对两种前处理方法的空白值、碰撞模式、加标回收率、内标因子的比较,对结果进行统计学判定。结果采用干灰化法比湿法消化处理样品测镉的回收率高,基质干扰小,检出限低,结果准确可靠。结论对于ICP-MS法检测此类食品样品中镉的前处理应择优选择干灰化法。 Objectives To compare effects of acid digestion and dry ashing pretreatments on the detection of cadmium in seasoning powder by ICP-MS,provides the reference for reasonable selection of the pretreatment method with ICP-MS for the determination of cadmium in food samples. Methods Using acid digestion and dry ashing pretreatments to dispose quality control sample of seasoning powder. Cadmium content was determined by ICP-MS method. The results were judged with statistical decision through multi angle comparison in blank value,collision model,recovery factor and internal factor. Results Dry ashing method is better than wet digestion in affects of sample recovery rate,matrix interference,detection limit for determination of cadmium,and its result is accurate and reliable. Conclusions Dry ashing method should be chosen as the best pretreatment method for cadmium determination in this kind of food sample by ICP-MS.
出处 《环境卫生学杂志》 北大核心 2014年第4期407-409,共3页 JOURNAL OF ENVIRONMENTAL HYGIENE
关键词 酸消解法 干灰化法 ICP-MS acid digestion, dry ashing, ICP-MS, cadmium
  • 相关文献

参考文献6

二级参考文献61

  • 1杨红霞,马新荣,李冰,孙德忠.电感耦合等离子体光谱/质谱法测定环境样品中的硼[J].岩矿测试,2004,23(4):273-277. 被引量:19
  • 2张新明.影响甲亚胺-H测硼法灵敏度有关条件的研究[J].土壤通报,1996,27(2):95-96. 被引量:4
  • 3汪金声,吴惠兰,王东晖.土壤有效硼测试方法的改进及结果分析[J].甘肃农业科技,1996,27(7):31-32. 被引量:8
  • 4叶正钱,魏幼璋,杨玉爱.甲亚胺与姜黄素测定土壤有效硼方法的对比研究[J].广东微量元素科学,1996,3(7):36-43. 被引量:14
  • 5BARANOV V I ,TANNER S D. A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) Part 1. the rf-field energy contribution in thermodynamics of ion-molecule reactions [J]. J Anal At Spectrom, 1999, 14: 1 133-1 142.
  • 6TANNER S D, BARANOV V I. A dynamic reaction cell for inductively coupled plasma mass spectrometry(ICPDRC-MS). Ⅱ. reduction of interferences produced within the cell[J]. J Am Soc Mass Spectrom,1999, 10:1 083-1 094.
  • 7TANNER S D, BARANOV V I, VOLLKOP U. A dynamic reaction cell for inductively coupled plasma mass spectrometry(ICP-DRC-MS)Part Ⅲ. optimization and analytical performance[J]. J Anal At Spectrom, 2000, 15:1 261-1 269.
  • 8BANDURA D R, BARANOV V I, TANNER S D. Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J]. Anal Chem, 2002, 74:1 497-1 502.
  • 9ANICICH V G. A survey of bimolecular ion-molecule reactions for use in modeling the chemistry of planetary atmospheres, cometary comae, and in- terstellar clouds: 1993 supplement[J]. The Astrophysical Journal Supplement Series, 1993, 84 (2) : 215-315.
  • 10KOYANAGI G K, BARANOV V I, TANNER S D, et al. An inductively coupled plasma/selectedion-flow tube mass spectrometric study of the chemical resolution of isobaric interferences[J]. J Anal At Spectrom, 2000, 15; 1 207-1 210.