期刊文献+

数字气压表误差及测量结果不确定度的研讨 被引量:4

The discussion and research of digital barometers error and uncertainty of measurement results
下载PDF
导出
摘要 以3台数字气压计为研究对象,对其进行性能测试,并对其结果进行误差分析、不确定度评定及验证。通过对大量测试数据的分析和研究表明:数字气压计的误差来源主要为线性误差和回程误差;不确定度主要来源于测量数据的重复性、标准器的误差、被测表的分辨力。高温、低温、常温测试试验结果显示:该型号的气压计示值误差不大于0.17hPa,线性误差不大于0.07hPa,回程误差不大于0.03hPa,不确定度不超过0.06hPa。 There are three digital barometers which are taken as research object to test theirperformance in this paper. Through performance testing of these barometers, the error of results wasanalyzed, besides, the uncertainty was evaluated and validated. Through analyzing and researchingextensive testing data, it shows that digital barometer's errors are mainly from linearity and hysterisis,and then the uncertainty of results is mainly from the repeatability of testing data, the error ofstandard meter and the resolution ratio of tested instrument. The error of this model digital barometershows that the error of result is less than 0.17 hPa, the linearity error is less than 0.07 hPa, thehysterisis error is less than 0.03 hPa, and then the uncertainty is not exceed 0.06 hPa after theexperiments in high temperature, low temperature and room temperature.
出处 《气象水文海洋仪器》 2014年第3期12-14,18,共4页 Meteorological,Hydrological and Marine Instruments
关键词 气压 性能测试 误差 不确定度 pressure performance test error uncertainty
  • 相关文献

参考文献3

  • 1JJF1059.1-2012,测量不确定度评定与表示[S].北京:国家质量监督检验检疫总局,2011.
  • 2李建英,贺晓雷.振筒气压仪性能测试[J].气象科技,2004,32(4):291-293. 被引量:3
  • 3施昌彦,叶德培,陈明华,等.JJF1094-2002测量仪器特性评定[S].国家质量技术监督局,2002.

二级参考文献2

  • 1气压计(国际建议No.97).国际法制计量组织OIML最新国际计量规程选集. 北京:中国计量出版社,1993.68-77
  • 2.国家计量检定规程汇编[Z].中国气象局产业发展与装备部,1998..

共引文献123

同被引文献21

引证文献4

二级引证文献23