期刊文献+

采用液压提升系统下闸有关设备载荷选取探讨

Application of Hydraulic Lifting System in Closure of Diversion Tunnels and Selection of Its Working Load
下载PDF
导出
摘要 利用液压提升系统在水电站进行导流底孔下闸,在国内尚属首次。通过向家坝水电站工程下闸所取得的一些检测数据,计算出闸门与门槽轨道间摩擦系数的取值范围,根据操作水头,计算出提升闸门所需载荷,就可以正确选取液压提升设备。 It is rare to close the diversion tunnels in hydropower stations with hydraulic lifting system. The practice in Xiangjiaba hydropower station is the first application in China. With the actual measurement data obtained from the closure procedure,friction coefficients between the gates and the tracks in gate slots are calculated. Working load of the hydraulic lifting system can be estimated under its working head. Then,the devices in the hydraulic lifting system can be selected based on the working load.
出处 《水电与新能源》 2014年第9期61-63,共3页 Hydropower and New Energy
关键词 液压提升系统 设备载荷 载荷选择 hydraulic lifting system working load load selection
  • 相关文献

参考文献2

二级参考文献3

  • 1中国水电顾问集团中南勘测设计研究院.金沙江向家坝水电站工程下闸蓄水专题报告[R]宜宾:中国长江三峡集团公司向家坝工程建设部,2012.
  • 2中国长江三峡集团公司向家坝工程建设部;中国水电顾问集团中南勘测设计研究院;同济大学.向家坝工程导流底孔采用液压提升系统操作闸门原型试验[R]宜宾:中国长江三峡集团公司向家坝工程建设部,2011.
  • 3中国长江三峡集团公司向家坝工程建设部;中国水电顾问集团中南勘测设计研究院.向家坝水电站下闸蓄水操作程序[R]宜宾:中国长江三峡集团公司向家坝工程建设部,2012.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部