期刊文献+

动力髋螺钉治疗股骨转子间骨折

下载PDF
导出
摘要 目的 观察动力髋螺钉治疗股骨转子间骨折的临床疗效,并总结其经验。方法 对58例股骨转子间骨折患者采用动力髋螺钉治疗。结果 全部58例患者经10~24个月随访,平均18个月,所有骨折均获得骨性愈合,关节功能恢复较为满意。优良率为93.1%。结论 动力髋螺钉是治疗股骨转子间骨折的理想方法之一。
出处 《航空航天医学杂志》 2014年第9期1251-1252,共2页 Journal of Aerospace medicine
  • 相关文献

参考文献6

  • 1张建政,刘树清.股骨粗隆间骨折//胥少汀,葛宝丰,徐印坎.实用骨科学[M].第四版.北京:人民军医出版社,2012:947-958.
  • 2Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end - result study using a new method of result evalua- tion. J Bone Joint Surg Am, 1969,51(4) :737 -755.
  • 3张林.股骨转子间骨折//田伟.实用骨科学[M].北京:人民卫生出版社,2008:450-453.
  • 4王满宜,主译.骨折治疗的AO原则[M].北京:华夏出版社,2003:441-453.
  • 5卢世壁,主译.坎贝尔骨科手术学[M].第9版.济南:山东科技术出版社,200l:577-594.
  • 6陈红卫,匡红,张根福,赵钢生,吴国林,潘骏,昊立军.微创动力髋螺钉治疗股骨转子间骨折[J].中华创伤杂志,2012,28(11):1010-1013. 被引量:6

二级参考文献17

  • 1Zuekerman JD, Koval KJ, Aharonoff GB, et al. A functional re- covery score for elderly hip fracture patients: I. development. J Orthop Trauma, 2000, 14( 1 ) :26 -30.
  • 2Cummings SR, Melton LJ. Epidemiology and outcomes of osteopo- rotic fractures. Lancet, 2002, 359 (9319 ) : 1761 - 1767.
  • 3Kaplan K, Miyamoto R, Levine BR, et al. Surgical management of hip fractures : an evidence - based review of the literature. ]I : intertrochanteric fractures. J Am Acad Orthop Surg, 2008, 16 ( 11 ) :665 -673.
  • 4Saarenpaa I, Heikkinen T, Ristiniemi J, et al. Functional com- parison of the dynamic hip screw and the Gamma locking nail in trochanteric hip fractures : a matched - pair study of 268 patients. Int Orthop, 2009, 33 ( 1 ) :255 - 260.
  • 5Papasimos S, Koutsojaanis CM, Panagopoulos A, et al. A ran- domised comparison of AMBI, TGN and PFN for treatment of un- stable trochanteric fractures. Arch Orthop Trauma Surg, 2005, 125(7) :462 -468.
  • 6Tristan MB, Robert G, Claire T, et al. A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31 - A2 fractures of the proximal part of the femur: a prospective randomized trial. J Bone Joint Sur$ ( Am ) , 2010, 92 ( 4 ) : 792 - 798.
  • 7Willoughby R. Dynamic hip screw in the management of reverse obliquity intertrochanteric neck of femur fractures. Injury, 2005, 36(1) :105 -109.
  • 8Wong TC, Chiu Y, Tsang WL, et al. A double - blind, pro- spective, randomised, controlled clinical trial of minimally inva- sire dynamic hip screw fixation of intertrochanteric fractures. In- jury, 2009, 40(4) :422 -427.
  • 9Waters TS, Gibbs DM, Dorrell JH, et al. Percutaneous dynamic hip screw. Injury, 2006, 37(8) :751 -754.
  • 10Im H, Jacobsen S, Sorme - Holm S, et al. Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important pre- dictor of a reoperation. J Bone Joint Surg (Am) , 2007, 89 ( 3 ) : 470 - 475.

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部