期刊文献+

端板型钢管混凝土半刚性组合节点拟动力试验 被引量:3

Pseudo-dynamic tests of endplate semi-rigid composite joints to CFST columns
下载PDF
导出
摘要 为了获悉地震作用下半刚性钢管混凝土组合节点的抗震性能和破坏形式,进行了2榀足尺钢管混凝土柱—组合梁单边螺栓端板连接组合节点拟动力试验。研究参数为端板类型。以Ispara地震波作为模拟地震拟动力试验的激励输入,对在地震作用下组合节点的荷载-位移关系滞回曲线、位移时程反应曲线、加速度时程反应曲线、动力放大系数、刚度和强度退化、耗能能力等进行了深入的分析,比较了平齐端板连接和外伸端板连接对组合节点抗震性能的影响。试验研究表明,端板型钢管混凝土半刚性组合节点具有良好的耗能能力和抗震性能,可以在多高层组合框架中推广和应用。 To know seismic behavior and failure modes of semi-rigid composite joints to concrete-filled steel tubular (CFST) columns under seismic action, two full scale endplate blind bolted specimens of composite joints between CFST columns and composite beams were carried out by pseudo-dynamic tests. The research parameter is endplate type. With Ispara seismic wave as the simulated seismic excitation input of pseudo dynamic test, the load-displacement relation hysteresis curves, displacement time history response curves, acceleration time history response curves, amplification coefficient, stiffness and strength degradation and energy dissipation capacity, etc. The effect of flush and extended endplate connection on seismic performance of composite joints was compared. The test results showed that the endplate typed composite joints to CFST columns behave semi-rigid characteristics, and have good energy dissipation capacity and seismic performance. They can be used in the multilayer and high-rise composite frames.
出处 《地震工程与工程振动》 CSCD 北大核心 2014年第4期57-63,共7页 Earthquake Engineering and Engineering Dynamics
基金 国家自然科学基金资助项目(51178156 50808062) 教育部新世纪优秀人才支持计划(NCET-12-0838)
关键词 钢管混凝土 组合节点 端板连接 拟动力试验 抗震性能 concrete-filled steel tubular composite joint endplate connection pseudo-dynamic test seismic behavior
  • 相关文献

参考文献7

二级参考文献52

  • 1肖岩,胡庆,郭玉荣,易伟建,朱平生.结构拟动力远程协同试验网络平台的开发研究[J].建筑结构学报,2005,26(3):122-129. 被引量:50
  • 2XIAO Yan,HU Qing,GUO Yurong,ZHU Pingsheng,YI Weijian.Network platform for remote structural testing and shared use of laboratories[J].Progress in Natural Science:Materials International,2005,15(12):1135-1142. 被引量:19
  • 3聂建国,秦凯,刘嵘.方钢管混凝土柱与钢-混凝土组合梁连接的内隔板式节点的抗震性能试验研究[J].建筑结构学报,2006,27(4):1-9. 被引量:29
  • 4ANSI/AISC 341-05 Seismic provisions for structural steel buildings [ S ]. Chicago : AISC, 2005.
  • 5Elremaily A F. Connections between steel beams and concrete-filled steel tube columns[ D]. Lincoln : University of Nebraska, 2002.
  • 6Ricles J M, Peng S W, Lu L W. Seismic behavior of composite concrete filled steel tube column-wide flange beam moment connections [ J]. Journal of Structural Engineering, 2004, 130(2) :223-232.
  • 7Herrera R, Ricles J M, Sause R. Seismic performance evaluation of a large-scale composite MRF using pseudo-dynamic testing[J]. Journal of Structural Engineering, 2008, 134(2) :279-288.
  • 8Chen C H, Hsiao B C, Lai J W, et al. Pseudo-dynamic test of a full-scale CFT/BRB frame: Part 2-Construction and testing [ C/CD ]// Proceedings of the 13th World Conference on Earthquake Engineering. Paper No. 2175. Vancouver: Canadian Society for Earthquake Engineering, 2004.
  • 9AISC 350-99 Load and resistance factored design specification for structural steel buildings[ S].
  • 10Chou C C, Uang C M. Cyclic performance of a type of steel beam to steel-encased reinforced concrete column moment connection[ J ]. Journal of Constructional Steel Research, 2002, 58(5-8): 637-663.

共引文献60

同被引文献18

  • 1陶忠,韩林海.中空夹层钢管混凝土的研究进展[J].哈尔滨工业大学学报,2003,35(z1):144-146. 被引量:23
  • 2GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 3Han L, Li W, Bjorhovde R. Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members [ J]. Journal of Constructional Steel Research, 2014(100) :211-228.
  • 4Nie J, Huang Y, Yi W, et al. Seismic behavior of CFRSTC composite frames considering slab effects [ J ]. Journal of Constructional Steel Research, 2012,68 ( 1 ) : 165-175.
  • 5李国强,石文龙,王静峰.半刚性连接钢框架结构设计[M].北京:中国建筑工业出版社,2007.
  • 6Wang J, Han L, Uy B. Behaviour of flush end plate joints to concrete-filled steel tubular columns [ J 1. Journal of Constructional Steel Research, 2009 (65):925-939.
  • 7Lob H Y, Uy B, Bradford M A. The effects of partial shear connection in composite flush end plate joints Part I- experimental study [ J ]. Journal of Constrnctional Steel Research, 2006,62(4) :378-390.
  • 8Ataei A, Bradford M A, Valipour H R. Experimental study of flush end plate beam-to-CFST column composite joints with deconstructable bolted shear connectors [ J ]. Engineering Structures, 2015 (99) : 616-630.
  • 9Mirza O, Uy B. Behaviour of composite beam - column flush end-plate connections subjected to low-probability, high- consequence loading [ J]. Engineering Structures, 2011(33) :647- 662.
  • 10Wang J, Wang J. Seismic behavior of b|ind bolted CFST frames with semi-rigid connections [ C ]//Proceedings of the l lth International Conference on Advances in Steel and Concrete Composite Structures. Beijing, 2015:652-657.

引证文献3

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部