期刊文献+

Readout electronics for CSR-ETF silicon strip array detector system

Readout electronics for CSR-ETF silicon strip array detector system
下载PDF
导出
摘要 A readout electronics has been developed for the silicon strip array detector system of HIRFL-CSR-ETF.It consists of 48 front end electronics(FEE)boards,12 PXI-DAQ boards and one trigger board.It can implement energy and time measurements of 4608 channels.Each FEE board is based on 6 ASICs(ATHED),which implements energy and time measurements of 96 channels.The PXI-DAQ board meets requirements of high-speed counting and amount of readout channels and can process signals of 4 FEEs.The trigger board is developed to select the valid events.The energy linearity of the readout electronics is better than 0.3%in the dynamic range of 0.1-0.7V.In the test with a standard triple alpha source,the energy resolution was 1.8%at 5.48 MeV.This readout electronics enables the silicon strip array system to identify particles of A<14. A readout electronics has been developed for the silicon strip array detector system of HIRFL-CSR-ETF.It consists of 48 front end electronics(FEE) boards,12 PXI-DAQ boards and one trigger board.It can implement energy and time measurements of 4608 channels.Each FEE board is based on 6 ASICs(ATHED).which implements energy and time measurements of 96 channels.The PXI-DAQ board meets requirements of high-speed counting and amount of readout channels and can process signals of 4 FEEs.The trigger board is developed to select the valid events.The energy linearity of the readout electronics is better than 0.3%in the dynamic range of 0.1-0.7 V.In the test with a standard triple alpha source,the energy resolution was 1.8%at 5.48 MeV.This readout electronics enables the silicon strip array system to identify particles of A≤ 14.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第4期46-49,共4页 核技术(英文)
基金 Supported by the National Natural Science Foundation of China(Nos.11005135 and 11079045) the Important Direction Project of the CAS Knowledge Innovation Program(No.KJCX2-YW-N27) the Foundation of director of Institute Modern Physics,CAS(No.Y207170SZ0)
关键词 探测器系统 电子 读出 阵列 能量分辨率 DAQ板 时间测量 Readout electronics PXI-DAQ Silicon strip Front end electronics Application specific integrated circuit
  • 相关文献

参考文献11

  • 1Qian Y, Su H, Kong J, et al. Chinese Physics C, 2013, 37: 016101.
  • 2Won E, Choi J H, Ha H, et al. arXiv preprint arXiv: 0704.1334.
  • 3Montafio L M. Silicon microstrip detectors, AIP Conf Proc, 2006, 857: 143-151.
  • 4Campabadal F, Fleta C, Key M, et al. Nucl Instrum Meth A, 2005, 552: 292-328.
  • 5Raymond M, Cervelli G, French M, et al. The CMS Tracker APV25 0.25/am CMOS readout chip, Sixth Workshop on Elec- tronics for LHC Experiments, CERN/LHCC/2000-041.
  • 6Kuijer P. Nucl Instrum Meth A, 2000, 447: 251-256.
  • 7Kong J, Su H, Chen Z Q, et al. Nucl Instrum Meth A, 2010, 622: 215-218.
  • 8Baron P, Atkin E, Blumenfeld Y, et al. IEEE Nucl Sci Conf R, 2003, 386-390.
  • 9Pollacco E, Atkin E, Auger F, et al. AIP Conf Proc, 2006, 831: 337-341.
  • 10Du Z W, Su H, Qian Y, et al. arXiv preprint arXiv: 1211.1087.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部