摘要 本文简要介绍基于飞行时间(TOF)技术的正电子发射断层扫描成像(PET)的基本原理以及用于TOF-PET探测器模拟常用的Geant4,GATE,DETECT2000等模拟工具包,回顾近年来相关研究,对基于Monte Carlo方法的各种TOF-PET模拟,对影响LSO/LYSO晶体TOF-PET时间分辨的各项因素的模拟进行综述,并对未来TOF-PET模拟发展提出展望。 A brief introduction of the principles of time of flight(TOF) positron emission tomography(PET) and simulation toolkits of simulation software Geant4, GATE, DETECT2000 commonly used for TOF-PET detector simulation. A brief review of documents relating to the various studies of Monte Carlo towards TOF-PET simulation studies are introduced and the various factors impacting the time resolution of LSO/LYSO TOF-PET and the TOF-PET simulation studies of the future development prospects are presented.
出处 《CT理论与应用研究(中英文)》 2014年第4期699-706,共8页 Computerized Tomography Theory and Applications
基金 中国科学院知识创新工程重要方向项目(重大疾病的高性能诊疗方法与技术Cluster)
关键词 TOF-PET 模拟 蒙特卡罗 TOF-PET simulation Monte Carlo
  • 相关文献

参考文献23

  • 1陈金达,徐瑚珊,胡正国,陈若富,唐彬,岳珂,余玉洪,章学恒,孔洁,臧永东,王建松,孙志宇,郭忠言.A TOF-PET prototype with position sensitive PMT readout[J].Chinese Physics C,2011,35(1):61-66. 被引量:1
  • 2Allison J, Amako K, Apostolakis J, et al. Geant4 developments and application[J]. IEEE Transactions on Nuclear Science, 2006, 53(1): 270-278.
  • 3Jan S, Santin G, Strul D, et al. GATE: A simulation toolkit for PET and SPECT[J]. Physics in Medicine and Biology, 2004, 49(19): 4543.
  • 4Cayouette F, Laurendeau D, Moisan C. DETECT 2000: An improved Monte-Carlo simulator for the computer aided design of photon sensing Photo-Optical Instrumentation Engineers4883 devices[J]. Proceedings of the Society of Applications of Photonic Technology 5, 2003, (5): 69-76.
  • 5Mintzer RA, Siegel SB. Design and performance of a new pixelated-LSO/PSPMT Gamma-ray detector for high resolution PET imaging[J]. Nuclear Science Symposium Conference Record, 2007, NSS'07. IEEE, 2007, (5): 3418-3422.
  • 6Aykac M, Bauer F, Williams CW, et al. Timing performance of Hi-Rez detector for time-of-flight (TOF) PET[J]. IEEE Transactions on Nuclear Science, 2006, 53(3): 1084-1089.
  • 7Szczesniak T, Moszynski M, Swiderski L, et al. A continuous crystal detector for TOF PET[J]. IEEE Transactions on Nuclear Science, 2010, 57(1): 40.
  • 8Kuhn A, Surti S, Karp JS, et al. Performance assessment of pixelated labr3 detector modules for time-of-flight PET[J]. IEEE Transactions on Nuclear Science, 2006, 53(3): 1090-1095.
  • 9Bateman JE, Connolly JF, Stephenson R, et al. The rutherford appleton laboratory's mark I multiwire proportional counter positron camera[J]. Nuclear Instruments and Methods in Physics Research, 1984, 225(1): 209-231.
  • 10Fonte P, Smirnitski A, Williams MCS, et al. A new high resolution TOF technology[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000, 443(1): 201-204.

二级参考文献26

  • 1孙熙杉,王石,张志成,马天予,刘亚强,吴朝霞,金永杰.闪烁晶体阵列中光子输运过程的Monte Carlo模拟[J].清华大学学报(自然科学版),2007,47(z1):942-946. 被引量:1
  • 2LIU Ji-Guo, LIU Shi-Tao et al. IEEE NSS Conf. Rec., 2007, 8(2): 3294.
  • 3Casey M E et al. IEEE Trans. Nucl. Sci., 1997, 44(3): 1109- 1113.
  • 4Moszynsky M et al. Nucl. Instrum. Methods A, 1996, 372(1): 51-58.
  • 5Pepin C M et al. IEEE NSS Conf. Rec., 2002, 2:655 660.
  • 6Moriya T et al. IEEE NSS Conf. Rec., 2007, 4:2842-2846.
  • 7WU Y et al. IEEE Tran. NUcl. Sci. 2008, 55(1): 463-468.
  • 8Mechmet Aykac et al. IEEE Tran. NUcl. Sci., 2006, 53(3): 1084-1089.
  • 9Moszynski Met al. IEEE Tran. NUcl. Sci., 2006, 53(5): 2484-2488.
  • 10LIU Ji-Guo et al. IEEE NSS Conf. Rec., 2007, 5(3): 3294- 3304.

共引文献8