期刊文献+

对数域的光学相干层析图像噪声模型分析

Analysis of noise model of optical coherence tomography image in logarithmic domain
下载PDF
导出
摘要 为了分析光学相干层析成像技术(OCT)的图像对数变换前后的斑点噪声分布模型,为图像去噪及其它图像处理过程提供参考,采用了先推导斑点噪声理论分布模型,再通过实验数据验证的方法。首先分析了对数变换前斑点噪声的统计特性,利用数学理论推导得到斑点噪声对数变换后的理论分布模型,然后用OCT心血管图像的平滑区域作为噪声的试验数据,得到变换前后斑点噪声的直方图分布数据,最后用理论分布模型对试验数据进行曲线拟合,取得了确定系数、均方根差和卡方检测的评价数据。结果表明,对数变换后斑点噪声分布符合FisherTippett分布。这一结果对OCT图像去噪等处理过程是有帮助的。 In order to analyze the speckle noise distribution model of optical coherence tomography ( OCT ) images before and after logarithm transformation and provide references for image de-noising and other image processing , theoretical distribution model of the speckle noise was deduced firstly and then was verified by experimental results .First of all, the statistical properties of the speckle noise before the logarithm transformation were analyzed .The distribution model of the speckle noise after logarithm transform was derived through the mathematical theory .Then, the smooth regions of cardiovascular OCT images were selected as the experimental data to obtain the histogram distribution of the speckle noise before and after the logarithm transformation .Finally, the experimental data were fitted by the theoretical distribution model and the evaluated data, such as R-square, root mean square error and X-square tests.The results prove that the noise distribution after logarithm transformation presents Fisher-Tippett distribution .The results are helpful for the de-noising on OCT images.
出处 《激光技术》 CAS CSCD 北大核心 2014年第6期848-853,共6页 Laser Technology
基金 国家自然科学基金资助项目(61272237 61272236)
关键词 图像处理 噪声模型 对数变换 光学相干层析图像 斑点噪声 image processing noise model logarithm transformation optical coherence tomography image speckle noise
  • 相关文献

参考文献16

  • 1HUANG D, SWANSON E A, UN C P, et al. Optical coherence tomography [J] . Science, 1991 ,254 (5035 ) : 1178 -1181.
  • 2FUJIMOTO J G, BOUMA B, TEAMEY G J, et al. New technology for high-speed and high-resolution optical coherence tomography [J]. New York Academy of Sciences, 1998,838 (I) : 95-107.
  • 3秦玉伟.光学相干层析成像用于微机电系统测量研究[J].激光技术,2013,37(5):664-667. 被引量:4
  • 4FERCHER A F, HITZENBERGER C K, KAMP G, et al. Meas- urement of intraocular distances by backscattering spectral interferometry[J]. Optics Communications, 1995 ,117 (5) :4348.
  • 5SCHMITT J M, XIANG S H, YUNG K M. Speckle in optical coherence tomography: an overview [J] . Journal of Biomedicsl Optics,1999,4(I) :95-105.
  • 6GOSSAGE K W, SMITH C M, KANTER EM, et al. Texture analysis of speckle in optical coherence tomography images of tissue phantoms[J] Physics in Medicine Biology, 2006,51 (6): 1563- 1575.
  • 7GOODMAN J W. Statistical opticsj M]. New York , USA:John Wiley & Sons Inc, 1985: 122-125.
  • 8GOODMAN J W. Statistical properties of laser speckle patterns [M] . Heidelberg, Germany : Springer-Verlag, 1980: 1-50.
  • 9KARAMATA B, HASSLER K, LAUBSCHER M, et al. Speckle statistics in optical coherence tomography [J] . Journal of the Optical Society of America,2005 , A22( 4) :593-596.
  • 10XIE H, PIERCE L E, ULABY FT. Statistical properties of logarithmically transformed speckle [J]. IEEE Transactions on Geoscience and Remote Sensing,2002,40(3): 721-727.

二级参考文献10

  • 1HUANG D,SWANSON E A, LIN C P,et al. Optical coherence tomography [ J]. Science, 1991,254(5035 ) : 1178-1181.
  • 2CHANG Sh D, MAO Y X, FLUERARU C,et al. Optical coherence tomography: technology and applications [ J ]. Proceedings of SPIE ,2009,7156 : 1-8.
  • 3FERCHER A F,DREXLER W,HITZENBERGER C K,et al. Op- tical coherence tomography-principles and applications [ J ]. Re- ports on Progress in Physics,2003,66 (239) : 239-303.
  • 4FERCHER A F. Ophthalmic interferometry: optics in medicine, biology, and environmental research [ C ]//Proceedings of the In- ternational Conference on Optics Within Life Sciences. Garmisch- Partenkirchen, Germany: Conference on Optics Within Life Sci- ences, 1990:221-228.
  • 5WIESAUER K, P1RCHER M, GOTZINGER E, et al. En-face scanning optical coherence tomography with ultra-high resolution for material investigation [ J ]. Optics Express, 2005, 13 ( 3 ) : i015-i024.
  • 6FERCHER A F,HITZENBERGER C K,KAMP G,et al. Measure- ment of intraocular distances by backscattering spectral interfere- merry[J]. Optics Communications,1995,117(1/2) : 43-48.
  • 7LEITHEB R, HIEZENBERGER C K, FERCHER A F. Perfor- mance of Fourier domain vs. time domain optical coherence tomo- graphy[J]. Optics Express,2003,11 (8) : 889-894.
  • 8de BOER J F, CENSE B, PARK B H, et al. Improved signal-to- noise ratio in spectral-domain compared with time-domain optical coherence tomography [ J ]. Optics Letters, 2003,28 ( 21 ) : 2067- 2069.
  • 9TARGOWSKI P, WOJTKOWSKI M, KOWALCZYK A, et al. Com- plex spectral OCT in human eye imaging in vivo[ J]. Optics Com- munications,2004,229 ( 1/6 ) :79 -84.
  • 10QIN Y W, ZHAO H, ZHUANG Zh Q, et al. High resolution spectral-domain optical coherence tomography using a thermal light source [ J ]. Optical and Quantum Electronics,2012,43 (6) : 83-90.

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部