期刊文献+

高功率激光装置输出光束相对光谱功率测量方法 被引量:1

Relative spectral power measurement of laser-pulse for high power laser facility
下载PDF
导出
摘要 针对SILEX-I超短超强脉冲激光装置输出光束光谱分布的精密测量问题,采用脉冲激光相对光谱功率来评价光谱分布,以溴钨灯为标准光源开展相对光谱功率测量方法的研究,获得相对光谱功率的理论计算公式。以SP2760光栅光谱仪作为光谱测量设备在SILEX-I激光装置上进行了光谱分布测量的验证实验,并给出了不确定度评定,获得了扩展相对不确定度1.7%的测量精度。测量结果显示,相对光谱功率分布与光栅光谱仪的原始光谱响应值分布具有显著的差异,可以更加准确地反映输出脉冲的光谱分布。 The relative spectral power is used for evaluating the spectral distribution ot uttraslaort laser pulse, lne reiauve spectral power measurement for ultrashort laser pulse is studied based on the standard illuminant of bromine-tungsten lamp, and analytical expressions of the relative spectral power are clearly given. Experimental results for the relative spectral power measurement on SILEX-I laser facility using SP2760 spectrometer show that the spectral distribution evaluated by the relative spectral power is significantly different comparing with the original spectral response. The uncertainty-analysis of experimental results is also given, and the extended relative uncertainty is 1.7 %.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2014年第10期66-70,共5页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(61377102)
关键词 光栅光谱仪 相对光谱功率 光谱辐射照度 标准灯 grating spectrometer relative spectral power spectral irradiance standard lamp
  • 相关文献

参考文献12

二级参考文献64

  • 1占春连,李燕梅,刘建平,李正琪.红外探测器光谱响应度的均匀性及直线性测试研究[J].应用光学,2004,25(6):34-37. 被引量:18
  • 2ANDOR G. Approximation function of spectral irradiance of standard lamps[J]. Metrologia, 1998, 35(4):427-429.
  • 3WALKER J H, SAUNDERS R D, JACKSON J K, et al. NBS Special Publication 250-20. Spectral irradiance calibrations[S]. Washington, D C: US Government Printing Office, 1987.
  • 4BEVINGTON P R. Data reduction and error analysis for the physical sciences [M]. New York: McGraw-Hill, 1969.
  • 5JOHN H,MATHEWS K,FINK D.数值方法(Matlab版)[M].第4版.周璐,陈渝,钱方,等译.北京:电子工业出版社,2005.
  • 6HUANG L K, CEBULA R P, HILSENRATH E.New procedure for interpolating NIST FEL lamp irradiances[J]. Metrologia, 1998,35 (4): 381-386.
  • 7HARRISON N J,FOX N P,SPERFELD P.et al. International comparison of radiation-temperature measurements with filtered deteclors over the lemperature rage 1380 K to 3100 K [J].Metrologia, 1998,35:283- 288.
  • 8YOON H W. NIST-PTB measurements of the radiometric temperatures of a high temperature black body using filter radiometers[J]. Metrologia,2000,137:377-380.
  • 9占春连 刘建平 李正琪 等.基于高温黑体的光谱辐射亮度的测试研究.应用光学,2006,27:71-75.
  • 10GENTILE T R, HOUSTON J M,CROMER C L. Realizalion of a scale of absolute spectral response using the National Institute of Standards and Technology high-accuracy cryogenic [J]. Appl Opt, 1996,135(22) : 1050-1058.

共引文献30

同被引文献15

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部