期刊文献+

基于EMI损伤检测技术的温度补偿研究 被引量:3

Temperature Compensation Research of Damage Detection Technology Based on EMI Method
下载PDF
导出
摘要 基于机电阻抗(EMI)方法的健康监测技术近年来迅速发展,但温度对该方法的影响使得EMI技术的发展受到了一定的阻碍。此研究以实验为基础分析了温度对基于EMI的损伤检测技术的影响,随后分别采用有效频率偏移方法和神经网络方法对EMI损伤检测技术做温度补偿,并对比分析了两者的补偿效果。实验研究表明温度的变化会引起EMI方法中导纳曲线的偏移,引起RMSD损伤指标的变化,从而影响对损伤程度的分析判断。通过有效频率偏移方法及神经网络方法作温度补偿后,均得到了比较理想的补偿效果,温度影响明显减小。通过对比得出神经网络方法的补偿效果更加明显。 Electro-mechanics impedance ( EMI ) based structure health monitoring has a rapid development in recent years. But the temperature effect on EMI technique hinders the development of this technique. An experiment was performed to research the temperature effect on EMI based damage detection technology. Both the effective frequency shift ( EFS) method and artificial neural network ( ANN) method were adopted to compensate the temperature effect, and the compensation result was analyzed to compare the efficiency between two methods. The experimental result shows that the admittance curve will shift with the increase of temperature in EMI method, the RMSD index is changed because of the temperature effect. So this effect can mislead the judgment of the damage detection. Good results are both obtained after the temperature compensation by EFS and ANN methods, and the ANN method is more effective by comparing of compensation result.
出处 《土木工程与管理学报》 2014年第3期7-11,33,共6页 Journal of Civil Engineering and Management
基金 国家重点基础研究发展计划(973计划)(2011CB013804) 国家自然科学基金(51278215)
关键词 机电阻抗 损伤检测 温度补偿 神经网络 electromechanical impedance damage detection temperature compensation artificial neural network
  • 相关文献

参考文献16

  • 1Liang C, Sun F P, Rogers C A. An impedance method for dynamic analysis of active material systems [ J ]. Journal of Vibration and Acoustics, Transaction of the ASME, 1994, 116(1) : 120-128.
  • 2Ayres J W, Lalande F, Chaudhry Z, et al. Qualitative impedance-based health monitoring of civil infrastruc- tures[ J]. Smart Materials and Structures, 1998, 7 (5) : 599-605.
  • 3Victor Giurgiutiu,Kent Harries,Michael Petrou,Joel Bost,Josh B.Quattlebaum.Disbond detection with piezoelectric wafer active sensors in RC structures strengthened with FRP composite overlays[J].Earthquake Engineering and Engineering Vibration,2003,2(2):213-223. 被引量:2
  • 4Yan W, Lim C W, Cai J B, et al. An electromechani- cal impedance approach for quantitative damage detec- tion in timoshenko beams with piezoelectric patches [J ]. Smart Materials and Structures, 2007, 16: 1390-1400.
  • 5Sepehry N, Shamshirsaz M, Bastani A. Electrome- ehanieal Impedance Modeling of Cantilever Beams with Embedded PZT Transducers [ C ]// International Con- ference on Advanced Intelligent Mechatronies. Piscat- away : IEEE,2010 : 569-574.
  • 6Park G, Kabeya K, Cudney H H, et al. Removing Effects Temperature Changes from Piezoelectric Im- pedance-based Qualitative Health Monitoring [ C ]// Proceedings of the SPIE-The International Society for Optical Engineering. USA : SPIE, 1998 : 103-114.
  • 7Sun F P, Chaudhry Z A, Liang C, et al. Truss struc- ture integrity identification using PZT sensor-actuator [ J ]. Journal of Intelligent Material Systems and Struc- tures, 1995, 6(1): 134-139.
  • 8Giurgiutiu V, Rogers C A. Recent Advancements in the Electro-mechanical ( E/M ) Impedance Method for Structural Health Monitoring and NDE [ C ]//Proceed- ings of SPIE - The International Society for Optical Engineering. USA: SPIE, 1998: 536-547.
  • 9Tseng K K,Wang Liangsheng. Smart piezoelectric tran- sducers for in situ health monitoring of concrete [ J ]. Smart Material Structure, 2004,13 (5) : 1017-1024.
  • 10Yang Yaowen, Liu Hui, Venu G M A, et al. Monito- ring damage propagation using PZT impedance trans- ducers[ J]. Smart Materials and Structures, 2009, 18 ( 4 ) : 045003.

二级参考文献29

  • 1[1]ACI (1987), Considerations for Design of Concrete Structures Subjected to Fatigue Loading, American Concrete Institute.
  • 2[2]Ayres T, Chaudhry Z and Rogers C (1996), "Quality Health Monitoring of Steel Bridge Joint via Piezoelectric Actuator/Sensor Patches," Proceedings, SPIE's 1996Symposium on Smart Structures and Integrated Systems,SPIE, 2719: 123-131.
  • 3[3]Bhalla S and Soh CK (2003), "Structural Impedance Based Damage Diagnosis by Piezo-transducers,"Earthquake Engineering and Structural Dynamics,32(12): 1897-1916.
  • 4[4]Bois C and Hochard C (2002), "Measurement and Modeling for the Monitoring of Damaged Laminate Composite Structures," 1st European Workshop on Structural Health Monitoring, July 10-12, 2002, Paris,France, pp. 425-432.
  • 5[5]Buyukozturk O and Hearing B (1998), "Failure Behavior of Precracked Concrete Beams Retrofitted with FRP,"ASCE Journal of Composites for Construction, 2(3):138-144.
  • 6[6]Cudney HH and Inman DJ (1998), "Piezoelectric Impedance-Based Qualitative Health Monitoring," 4th ESSM and 2nd MIMR Conference, G. R. Tomlinson and W. A. Bullogh (Editors), Harrogate, U.K., pp. 795-785.
  • 7[7]Fyfe Company LLC (2000), Tyfo UC Composite Laminate Strip System, Material Specification Sheet.
  • 8[8]Giurgiutiu V, Reynolds A and Rogers CA (1999),"Experimental Investigation of E/M Impedance Health Monitoring of Spot-Welded Structural Joints,"Journal of Intelligent Material Systems and Structures,Technomic Pub., USA, 10(10): 802-812.
  • 9[9]Giurgiutiu V and Rogers CA (1999), "Recent Progress in the Application of E/M Impedance Method to Structural Health Monitoring, Damage Detection and Failure Prevention," 2nd International Workshop of Structural Health Monitoring, Sept. 8-10, 1999, Stanford U., CA,pp. 298-307.
  • 10[10]Giurgiutiu V and Zagrai AN (2001), "Embedded Self-Sensing Piezoelectric Active Sensors for Online Structural Identification," ASME Journal of Vibration and Acoustics, 124:116-125.

共引文献1

同被引文献12

引证文献3

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部