钢筋混凝土保护层厚度控制不到位已经成为结构施工的质量通病,从标准规范、设计、施工等角度对造成这一问题的主要原因进行了分析,给出了提高设计水平并完善设计规范、严格控制施工质量、大力推广钢筋定位件等提高钢筋混凝土保护层厚度保证率的建议。
Poor control of concrete cover has become a common quality problem in structure construction. After the discussion on standards, design and construction, some suggestions for increasing the concrete cover guarantee rate of steel bars are given in this article, such as improving design level and perfecting the design specifications, controlling construction quality strictly and promoting the steel bars positioning members.