通过对某三角形框架-核心筒结构高层建筑进行结构复核、房屋损伤及混凝土材料强度检测、结构倾斜和基础不均匀沉降测量,依据现行抗震鉴定标准对其进行抗震鉴定,找出结构存在的缺陷,对该建筑的改造提供合理的依据和详实的数据。
In order to provide reasonable basement and accurate data for the rebuilt of a triangle Framecorewall Structure,inspection and test were carried out,such as repetition measurement of structure,detection of building damage,strength inspection of concrete,measurement of building gradient and different settlement,etc. The seismic resistance of building structure were analyzed to find out structure defects.
出处
《工程质量》
2014年第10期65-69,共5页
Construction Quality
关键词
框架-核心筒结构
抗震鉴定
抗震验算
frame-corewall structure
seismic appraisal
antiseismic checking calculation