摘要
建立了适合大批量低含量Re地质样品的测定方法,0.2 g样品通过HF,HNO3分解后在2 mol/L的HCl介质中用阴离子交换树脂进行振荡吸附,然后用HNO3(1+1)解脱,同位素稀释等离子体质谱法测定。
Separation and determination are necessary for Re in geological samples because the content of Re is normally at ng/g level. A simple method was reported for the determination of Re in large amounts of geological samples in this paper. 0. 2 g of samples were digested with HF and HNO3. Re was adsorbed with anion exchange resin on a vibrator and desorbed with HNO3 ( 1 + 1 ). The samples were measured by ID-ICP-MS. The proposed method is very simple and it can be used for routine determination of Re in large amounts of geological samples.
出处
《分析试验室》
CAS
CSCD
北大核心
2014年第10期1229-1232,共4页
Chinese Journal of Analysis Laboratory