摘要
介绍湖北兴瑞化工有限公司第1期15万t/a离子膜法烧碱装置运行情况。在高电流密度下通过严格控制各项工艺指标及规范操作,可确保该装置长期稳定运行。
The running station of 150 kt/a ion-exchange membrane caustic soda plant which was the first-stage chlor- alkali project of Hubei Xingrui Chemical Co. , Ltd. was introduced. Strict control of each process parameter and standardized operation at high current density could ensure long-period stable running of the plant.
出处
《氯碱工业》
CAS
2014年第10期19-21,共3页
Chlor-Alkali Industry
关键词
膜极距电解槽
电流密度
运行经验
membrane-thickness electrode-distance electrolyzer
current density
running experience