期刊文献+

预应力钢绞线加固混凝土短柱抗震性能研究 被引量:10

Seismic Behavior of RC Columns Strengthened with Prestressed Steel Wires
原文传递
导出
摘要 为研究预应力钢绞线加固钢筋混凝土(RC)短柱的抗震特性,对7个试件进行了低周反复加载试验.试验研究了轴压比、钢绞线配置特征值和预应力水平对加固短柱抗震性能的影响.结果表明,预应力钢绞线可有效改善RC短柱的抗震性能,延性和耗能能力显著提高,与未加固试件PC1相比,预应力钢绞线加固短柱的位移延性系数、累积耗能能力最大值分别提高1.87倍和6.78倍;钢绞线配置量及预应力水平对加固柱滞回曲线有明显的影响,其它条件相同时,钢绞线配置量大或者预应力水平较高的试件滞回曲线较饱满;对于低轴压比(n≤0.30)试件,钢绞线配置特征值达到0.119、预应力水不小于0.40时即可获得较好的抗震性能.在试验基础上,提出了预应力钢绞线加固RC圆形短柱的受剪承载力计算公式,计算结果与试验值总体吻合良好.成果为预应力钢绞线加固RC短柱提供了参考数据和设计计算方法. In order to research the dynamic properties of the strengthening RC short columns with prestrssed steel wires (PSW), seven RC columns were tested under cyclic load and constant axial. Under low frequency cyclic loading, test phenomena were described. Experimental data are analyzed and compared, and the effects of configuration index of PSW, prestressing level of PSW and axial compression ratio on the seismic behavior are studied. The results show that the seismic performance of the retrofitted specimens could be effectively enhanced, ductility and energy dissipation are improved significantly. The biggest displacement ductility factor and accumulated energy dissipation of the columns strengthened with PSW are 1.87 times and 6.78 times higher respectively than that of the un-strengthened column. The seismic performance of the retrofitted columns can be improved significantly by increasing the configuration index and/ or the prestressed level of PSW. If the configuration index of PSW is bigger than 0.119, the prestressed level reaches 0.40, the seismic performance of the retrofitted specimens can be improved effectively when the axial load ratio is lower than 0.3. Based the test results, the calculating formulas of the shear capacity of RC short columns strengthened with PSW were proposed ,which may be useful for engineering design and further study.
作者 邓宗才 李辉
出处 《应用基础与工程科学学报》 EI CSCD 北大核心 2014年第5期941-951,共11页 Journal of Basic Science and Engineering
基金 国家自然科学基金项目(50978006)
关键词 预应力钢绞线 短柱 抗震加固 抗震性能 抗剪承载力 prestressed steel wires short columns seismic retrofit seismic behavior shearbearing capacity
  • 相关文献

参考文献10

  • 1Priestley M J N, Seible F, Xiao Y. Steel jacket retrofitting of reinforced concrete bridge columns for enhanced shear strength, Part 2 :test results and comparison with theory[ J]. ACI Structure Journal, 1994,91 (5) :537-551.
  • 2Wu Y F, Griffith M C, Oehlers D J. Improving the strength and ductility of rectangular reinforced concrete columns through composite partial interaction test [ J ]. Journal of Structure Engineering, ASCE,2003,129 ( 9 ) : 1183-1190.
  • 3叶列平,赵树红,李全旺,岳清瑞,张轲.碳纤维布加固混凝土柱的斜截面受剪承载力计算[J].建筑结构学报,2000,21(2):59-67. 被引量:95
  • 4Saatcioglu M, Yalcin C. External prestressing concrete columns for improved shear resistance [ J ]. Journal of Structure Engineering, ASCE, 2003,129 ( 8 ) : 1057 -1070.
  • 5Hasan A, Moghaddam. Seismic retrofit of large-scale reinforced concrete columns by prestressed high-strength metal strips [ C ]. Proceedings of the 2009 Structures Congress, ASCE. Austin, Texas : American Concrete Institute, 2009 : 2863- 2872.
  • 6Moochul S, Bassem A. Seismic repair of RC bridge piers using shape memory alloys [ C ]. Proceedings of the 2011 Structures Congress. ASCE. Las Vegas, Nevada :American Concrete Institute,2011:2056-2065.
  • 7郭子雄,张杰,李传林.预应力钢板箍加固高轴压比框架柱抗震性能研究[J].土木工程学报,2009,42(12):112-117. 被引量:29
  • 8郭子雄,张杰,杨勇.设置外包预应力钢板箍RC短柱抗震性能研究[J].哈尔滨工业大学学报,2006,38(1):140-144. 被引量:25
  • 9邓宗才,郭俊平,肖锐.一种预应力钢绞线加固混凝土柱体的张拉锚固系统:中国,201010152467.X[P].2010-08-25.
  • 10吕志涛,石平府,周燕勤.圆形、环形截面钢筋混凝土构件抗剪承载力的试验研究[J].建筑结构学报,1995,16(3):13-20. 被引量:37

二级参考文献20

  • 1郭子雄,张杰,杨勇.温度预应力钢板箍加固RC短柱有限元分析[J].工程抗震与加固改造,2005,27(2):50-54. 被引量:2
  • 2郭子雄,张杰,杨勇.设置外包预应力钢板箍RC短柱抗震性能研究[J].哈尔滨工业大学学报,2006,38(1):140-144. 被引量:25
  • 3Priestley M J , Seible F, Xiao Y, et al. Steel jacket retrofitting of reinforced concrete bridge columns for enhanced shear strength--part comparison with theory [ J ] 2: test results and ACI Structural Journal,1994,91 (5) :537-551.
  • 4Hussain M A, Driver R G. Discussion of " retrofit of reinforced concrete columns using partially stiffened steel jackets" by Yan Xiao and Hui Wu [ J ]. Journal of Structural Engineering, ASCE,2005,131 ( 2 ) : 364-365.
  • 5Gamble W L, Hawkins N M, Kaspar I I. Seismic retrofitting experience and experiments in Illinois [ C ]//Proceedings of 5th National Workshop on Bridge Research in Progress, National Center for Earthquake Engineering Research. New York :State University of New York at Buffalo, 1996: 245- 250.
  • 6Saatcioglu M, Yalcin C. External prestressing concrete columns for improved seismic shear resistence [ J ]. Journal of Structural Engineering, ASCE, 2003, 129 ( 8 ) : 1057-1070.
  • 7Munawar A H, Robert G C. Experimental study on the seismic performance of externally confined reinforced concrete columns [ C ]//Proceeding of 13th WCEE. Canada :2004.
  • 8吕志涛,南京工学院学报,1980年,3期
  • 9赵树红,学位论文,1999年
  • 10日本铁道综合技术研究所,炭素纤维铁道高架桥柱 耐震林强工法设计与施工指针,1996年

共引文献171

同被引文献69

引证文献10

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部