Cantilever with immobilized antibody for liver cancer biomarker detection 被引量:1

Cantilever with immobilized antibody for liver cancer biomarker detection
原文传递
导出
摘要 A novel cantilever array-based bio-sensor was batch-fabricated with IC compatible MEMS technology for precise liver cancer bio-marker detection. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization, thus the adsorption of the cancer biomarker takes place only in the local region of the cantilever instead of the whole lever, and the effect of adsorption-induced k variation can be dramatically reduced. These structural features offer several advantages: high sensitivity, high throughput, high mass detection accuracy, and a portable system. In addition, an analytical model has been established to eliminate the effect of the adsorption-induced lever stiffness change and has been applied to the precise mass detection of the cancer biomarker AFP; the experimentally detected AFP antigen mass by the sensor (7.6 pg/mL) is quite close to the calculated one (5.5 pg/mL), two orders of magnitude better than those of the fully antibody-immobilized cantilever sensor. These approaches can promote real applications of the cantilever sensors in cancer diagnosis. A novel cantilever array-based bio-sensor was batch-fabricated with IC compatible MEMS technology for precise liver cancer bio-marker detection. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization, thus the adsorption of the cancer biomarker takes place only in the local region of the cantilever instead of the whole lever, and the effect of adsorption-induced k variation can be dramatically reduced. These structural features offer several advantages: high sensitivity, high throughput, high mass detection accuracy, and a portable system. In addition, an analytical model has been established to eliminate the effect of the adsorption-induced lever stiffness change and has been applied to the precise mass detection of the cancer biomarker AFP; the experimentally detected AFP antigen mass by the sensor (7.6 pg/mL) is quite close to the calculated one (5.5 pg/mL), two orders of magnitude better than those of the fully antibody-immobilized cantilever sensor. These approaches can promote real applications of the cantilever sensors in cancer diagnosis.
出处 《Journal of Semiconductors》 EI CAS CSCD 2014年第10期60-65,共6页 半导体学报(英文版)
基金 Project supported by the State Key Development Program for Basic Research of China(Nos.2011CB933102,2013YQ16055103) the National Natural Science Foundation of China(Nos.61234007,61201104)
关键词 MEMS cantilever mass detection liver cancer biomarker local reaction adsorption-induced stiffnesschange MEMS cantilever mass detection liver cancer biomarker local reaction adsorption-induced stiffnesschange
  • 相关文献

参考文献16

  • 1Arlett J L, Myers E B, Roukes M L, et al. Comperative advan- tages of mechanical biosensors. Nature Nanotechnology, 2011, 6:203.
  • 2Raiteri R, Grattarola M, Butt H J, et al. Micromechanical cantilever-based biosensors. Sensors and Actuators B, 2001, 79: 115.
  • 3Alvarez M, Lechuga L M. Microcantilever-based platforms as biosensing tools. Analyst, 2010, 135:827.
  • 4Hierlemann A, Brand O, Hagleiter C, et al. Microfabrication techniques for chemical/biosensors. Proc IEEE, 2003:839.
  • 5Lavrik N V, Sepaniak M J, Datskos P G, et al. Cantilever trans- ducers as a platform for chemical and biological sensors. Review of Scientific Instruments, 2004, 75:2229.
  • 6Johnson B N, Mutharasan R. Biosensing using dynamic-mode cantilever sensors: a review. Biosensors and Bioelectronics, 2012, 32:1.
  • 7Lee J H, Kim T S, Yoon K H. Effect of mass and stress on resonant frequency shift of functionalized Pb(Zro.52Ti0.48)O3 thin film microcantilever for the detection of C-reactive protein. Appl Phys Lett, 2004, 18:3187.
  • 8Hwang K S, Eom K, Lee J H, et al. Dominant surface stress driven by biomolecular interactions in the dynamical response of nanomechanical microcantilevers. Appl Phys Lett, 2006, 89" 173905.
  • 9Hwang K S, Lee S M, Kim S K, et al. Micro- and nanocantilever devices and systems for biomolecule detection. Annu Rev Anal Chem, 2009, 2:77.
  • 10Albrecht T R, Grutter P, Home D, et al. Frequency modulation detection using high-Q cantilevers for enhanced force micro- scope sensitivity. J Appl Phys, 1991, 69:668.