摘要 介绍了DL/T 645规约与IEC60870-5-104规约转换的模型及其软件实现,实现了智能配变终端既能实时监测电能表的数据,又能实时与主站通信。经过反复调试运行,验证了该规约转换的可靠性。 This article introduces a conversion model of the DL/T 645 protocol and IEC60870-5-104 protocol and its software implementation. It is conducive to realize that the intelligent distribution terminal can monitor the data of watt-hour meter in real time , and can communicate with the master station in real time. With multiple debugging and running, the conversion proves to be reliable.