摘要 为了实现凸度仪对热轧板带材的在线凸度检测功能,研制能快速响应的高压充气电离室探测器是一项关键工作。通过可靠的方法估算电离室的响应时间可以为凸度仪电离室的研制提供指导,降低研发成本。论文提出一种基于范式方程修正的估算方法,估算出了凸度仪电离室的响应时间。分析结果表明,该方法能够有效地估算电离室的响应时间,对凸度仪电离室探测器的研制具有参考意义。 In order to achieve online detection of the crown of hot-rolled steel strips,it's a critical job to develop high gas-pressurized ionization chamber detectors which can response rapidly.Estimating the response time of ionization chamber in profile gauge by reliable methods can direct its development and reduce the cost.This paper proposed a estimation method based on Van der Waals equation correction,by which the response time of ionization chamber in profile gauge was estimated.Analysis results indicated that this method can effectively estimate the response time of ionization chamber,which had reference significance to the development of ionization chamber detectors in profile gauge.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2014年第5期553-556,共4页 Nuclear Electronics & Detection Technology
基金 北京市科技计划资助项目(Z080903027508) 国家自然科学基金资助项目(11205095)
关键词 响应时间 范德瓦尔斯方程 高压充气电离室 凸度仪 response time Van der Waals equation high gas-pressurized ionization chamber profile gauge
  • 相关文献

参考文献5

二级参考文献11

  • 1徐德贵,孙艳秋.莱钢1500mm热连轧带钢生产线工艺和设备特点[J].轧钢,2006,23(3):35-37. 被引量:12
  • 2谈春明,邬海峰,卿上玉,王立强.Kr、Xe高压气体电离室时间特性研究[J].原子能科学技术,2006,40(B09):139-141. 被引量:2
  • 3汪志诚.热力学统计物理(第二版)[M].北京:高等教育出版社,1998.15,124-127.
  • 4NEVES P N B, CONDE C A N, TAVORA L M N. A new experimental technique for positive ion drift velocity measurements in noble gases: Results for xenon ions in xenon[J]. Nuclear Instruments and Methods in Physics Research A, 2007, 580(1): 66-69.
  • 5EWING R G, ATKINSON D A, EICEMAN G A, et al. A critical review of ion mobility spec- trometry for the detection of explosives and explosive related compounds[J]. Talanta, 2001,54(3): 515-529.
  • 6NEVES P N B, CONDE C A N, TAVORA L M N. A new experimental technique for positive ion drift velocity measurements in noble gases: Results for xenon ions in xenon[J]. Nuclear In- struments and Methods in Physics Research A, 2007, 580(1): 66-69.
  • 7汪青海.高压气体电离室中离子漂移速度的研究[D].北京:清华大学,2010.
  • 8王立强,郑健,王振涛.高压气体电离室中离子漂移速度的研究[R].北京:中国核学会,2009.
  • 9AMARO F D, CONCEICAO A S, VELOSO J F, et al. Operation of a single-GEM in noble gases at high pressures[J]. Nuclear Instruments and Methods in Physics Research A, 2007, 579 (1) : 62-66.
  • 10汪青海,王立强,郑健.高压气体电离室中离子漂移速度的实验测量[J].原子能科学技术,2011,45(8):995-998. 被引量:3