摘要 场地衰减偏差是评估半电波暗室(SAC)是否满足30 MHz^1 GHz射频电磁场辐射发射测试要求的关键指标。针对某SAC场地衰减偏差的多次测量结果,从扫频测量参数、天线塔和电缆组件、测量天线的巴伦阻抗特性、溯源场地特性差异等方面进行剖析,讨论导致测量结果差异的主要因素。 Deviation of site attenuation is a critical index that is used to evaluate whether a semi-anechoic chamber ( SAC ) meets the requirements for radiated emission tests of radio-frequency electromagnetic field in the frequency range of 30 MHz to 1 GHz. The muhiple test results of deviation on site attenuation of a SAC, which were obtained from various perspectives, such as sweep frequency parameters, antenna tower and cable assembly, balun impedance characteristics of antenna, are ananlyzed. And the major factors resulting in the differences are discussed.
出处 《安全与电磁兼容》 2014年第5期34-40,共7页 Safety & EMC
关键词 场地衰减偏差 试验场地确认 自由空间天线系数 双天线系数 参考场地法 deviation of site attenuation test site validation free-space antenna factor dual-antenna factor reference site method
  • 相关文献

参考文献4

  • 1IEC/CISPR 16-1-4:2012 Specification for radio dislurhanceand immunity measuring apparatus and methods — Part1-4: Radio disturbance and immunity measuring apparatus-Antennas and test for radiated disturbance measuremenlsfS].2012.
  • 2ANSI C63.5-2006 American National Standard forElectromagnetic Compatibility -Radiated EmissionMeasurements in Electromagnetic Interference (EMI) Control—Calibration of Antennas (9 kHz to 40 GHz)[S]. 2006.
  • 3(^ISPH 16-1-5:2012. Sperificitlinn for radio dislurbanceand immunity measuring apparatus and methods -Part1-5: Hadio disturl>ance anH immunity measuring apparalus-Sperifirations and validation procedures for CALTS atxlHKFrS from 30 MHz to 1 000 MHz|S|. 2012.
  • 4W. M ii liner, A. Kriz. SITK ATTENUATION OFLIMITKI) - SIZE GROUND PLANES KOH VERTICALPOLA RISATI ON [OL].http://rf.seihers(iforf—laboratories.at/filea(imin/upload.s/intranet/<lateien/2001_Paper_Site_Attenualiori_of_limited.pdf, 2014-05.