期刊文献+

HRB400带肋钢筋盘条脆断原因分析 被引量:4

Brittle fracture cause analysis of HRB400 ribbed bar coil
下载PDF
导出
摘要 通过对HRB400带肋钢筋盘条脆断试样进行金相组织、晶粒度、微区成分偏析、非金属夹杂物的检测分析,找出了盘条脆断的原因,即盘条在斯太尔摩辊道上的风机开启区域"打爬行",冷却时间过长,产生了脆性组织,使盘条局部塑性降低,产生脆性断裂。 The brittle fracture cause of HRB400 ribbed bar coil was found out based on detection and analysis of the micro- structure, grain size , micro-zone segregation and non-metallic inclusions of the fracture samples. As the ribbed bar coil slipped along the fan-open area of the Stelmor roller, its cooling time was too long to form brittle microstructure, so that lo- cal plasticity reduction was induced, and lead to the brittle fracture of the ribbed bar.
出处 《轧钢》 2014年第5期68-70,共3页 Steel Rolling
关键词 带肋钢筋盘条 脆断 金相组织 成分偏析 ribbed bar coil brittle fracture microstructure composition segregation