期刊文献+

高速铁路开关设备选型问题研究 被引量:1

Research On Switch Equipment Selection of High-speed Railway
下载PDF
导出
摘要 我国电气化铁路牵引供电的基本要求是:200 km/h及以下采用户内空气绝缘开关设备(27.5 kV单相单极居多),200~250 km/h采用户外敞开式开关设备(2×27.5 kV和55 kV单相双极居多),250 km/h以上采用户内气体绝缘开关设备(2×27.5 kV单相双极居多).伴随着高速铁路的快速发展,标准中规定使用的电气化铁道开关设备存在的问题也逐渐暴露出来. The basic requirement of traction power supply for electrified railway of our country is: indoor air insulated switch equipment is used at 200 km/h and below (single-phase unipolar 27.5 kV mostly) ; outdoor open switch equipment is used at 200-250 km/h (single-phase bipolar 2 ×27.5 kV and 55 kV mostly), indoor gas insulated switch equipment is used at more than 250 km/h (single-phase bipolar 2 × 27.5 kV mostly). Along with the rapid development of high-speed railway, the problems of electrified railway switch equipment which the standard stipulates have gradually exposed.
出处 《铁道机车车辆》 2014年第5期113-119,共7页 Railway Locomotive & Car
关键词 铁路 电气化 开关设备 铠装金属封闭 气体绝缘 选型 railway electrify switch equipment armored metal-enclosed gas insulation selection
  • 相关文献

参考文献4

  • 1宋果,崔景春,袁大陆.2004年国家电网公司高压开关运行分析[J].高压开关,2005,22(3):7-13.
  • 2中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.GB/T4787-2010高压交流断路器用均压电容器[s].中国标准出版社,2011.
  • 3中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.GB39063.6~40.5kV交流金属封闭开关设备和控制设备[s].中国标准出版社,2006.
  • 4GB1122.高压开关设备与控制设备标准的共用技术要求[s].