摘要 针对某农饮工程清水池施工中出现大面积裂缝的情况,经对池体抗浮验算、裂缝宽度计算及工程质量检测分析,得出施工中水池基坑未及时回填、降雨产生积水、地下水位升高、浮托力超过水池自重是造成池体裂缝的主要原因.工程通过采取有效的加固措施,使水池运行验收合格,为类似工程提供借鉴意义. Aimed at the large area fissures condition which come into being in construc ting the clean water pond of a rural drinking water project and by the pond body checking computation against flotation,break width calculation and engineering quality detecting and analysis,the main reason of pond body break is that the pond excavation wasn't filled promptly,rainfall resulted in ponding and underground water level rised and the uplift pressure of the pond exceeded its dead load. The effective reinforcement measures was adopted and the operation acceptance of the pond passed. It can be referred for the similar projects.
出处 《江西水利科技》 2014年第3期212-216,共5页 Jiangxi Hydraulic Science & Technology
关键词 水池 裂缝原因 低压自流式排水灌浆 无收缩修复砂浆 高强环氧砂浆 Pond Break reason Low pressure gravity drainage grouting No shrink repairing mortar High strength epoxy mortar
  • 相关文献

参考文献7

二级参考文献17

  • 1才庆祥,余静.矿区铁路运输系统可靠性研究[J].煤炭学报,2004,29(5):536-539. 被引量:8
  • 2刘声远,孙颖,齐向阳.钢筋混凝土水池裂缝的分析与处理[J].辽宁工程技术大学学报(自然科学版),2007,26(2):228-231. 被引量:9
  • 3于卫平.水池裂缝产生的原因及防治措施[J].科技咨询导报,2007(18):36-36. 被引量:2
  • 4GB 50069-2002.给水排水工程构筑物结构设计规范[S].,..
  • 5CECS 138-2002,给水排水工程钢筋混凝土水池结构设计规范[S].
  • 6GB50334-2002,城市污水处理厂工程质量验收规范[s].
  • 7GB50010-2002.混凝土结构设计规范[S].[S].,..
  • 8CECS138:2002.给水排水工程钢筋混凝土水池结构设计规程[S].[S].,..
  • 9王铁梦.工程结构裂缝控制[M].北京:中国建筑工业出版社,2001..
  • 10朱伯芳.水工混凝土结构的温度应力与温度控制[M].北京:水力电力出版社,1999..

共引文献29

同被引文献1

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部