摘要 介绍列控车载系统的实时Profibus总线系统,结合Subset-056/057标准,对该总线系统的数据处理流程进行详细描述,指出其与标准Profibus数据处理流程的差异。结合这种差异性,对列控车载系统Profibus多主站系统的实时性进行详细分析,定量给出关键参数TTR的选取方法,并通过实例进一步描述该选取方法。列控车载设备在实验室的长时间稳定运行证明该参数选取方法的正确性。 The paper introduces a real-time Profibus system of the train control system, describes the data processing fl ow of the Profi bus system combining with subset056/057 standard, and points out the differences in data processing flow between the Profibus system with the subset056/057 standard. For these differences, the paper presents a detailed analysis of the multi-master on-board train control system with selection method of key parameter TTR, and gives further description of the selection method through examples. The correctness of the parameter selection method is proved by long and stable operation of the onboard train control equipment in lab.
出处 《铁路通信信号工程技术》 2014年第5期4-7,共4页 Railway Signalling & Communication Engineering
关键词 PROFIBUS 列车控制 主站 实时性分析 Profi bus train control master station real-time feature analysis
  • 相关文献

参考文献8

  • 1INTERNATIONAL STANDARD.IEC61158,Digital data communications for measurement and control-Fieldbus for use in industrial control systems[S].
  • 2G.Agrawal,B.Chen,W.Zhao,and S.Davari.Guaranteeing synchronous message deadline with the timed token medium access control protocol[J].IEEE Trans.Comput.,vol.43,pp.327-339,Mar.1994.
  • 3Q.Zheng and K.G.Shin.Synchronous bandwidth allocation in FDDI networks[J].IEEE Trans.Parallel Distrib.Syst.,vol.6,pp.1332-1338,Dec.1995.
  • 4E.Tovar,F.Vasques.Real-Time Fieldbus Communications Using Profibus Networks[J].IEEE Transactions on Industrial Electronics,1999,46 (6):1241-1251.
  • 5Hung S H.Experimental Performance Evaluation of Profibus-FMS[J].IEEE Robotics and Automation Magazine,2000,7 (4):64-72.
  • 6侯维岩,费敏锐,阳宪惠,Lutz Rauchhaupt.令牌目的循环时间T_(TR)对现场总线PROFIBUS测控周期的影响[J].仪器仪表学报,2005,26(4):399-402. 被引量:19
  • 7ERTMS/ETCS.STM FFFIS Safe Time Layer,subset056.1SSUE:2.2.0[S].
  • 8ERTMS/ETCS.STM FFFIS Safe Link Layer,subset057.ISSUE:2.2.0[S].

二级参考文献6

  • 1William Stallings. Local & metropolitan area networks (fifth edition) '[M]. Prentice-Hall ,Inc. , 1997.
  • 2W. Hou, H. Adamczyk, L. Rauchhaupt. Performance evaluation of the RFieldbus system [Z]. IFAC FET'03 Proceedings, Aveiro ,Portugal ,July 2003,123~129.
  • 3EN 50170.General purpose field communication system' [M ]. European Standard White Paper, CENELEC,1996,Vol. 2/3.
  • 4E. Tovar, F. Vasques. Cycle time properties of the PROFIBUS timed-token protocol [J]. Computer Communications, 1999,22 : 1206~ 1216.
  • 5Technical Guideline of PROFIBUS-DP Extension to EN50170-Version 2.0[M]. PNO* ,April 1998.
  • 6R. Grow. A timed token protocol for local area networks [J]. Proceedings of Electro'82,May 1982,3~ 17.

共引文献18