期刊文献+

Coupler静脉吻合器用于乳腺癌游离腹部皮瓣乳房重建疗效分析 被引量:4

Assessment of the Coupler therapeutic effect for venous anastomosis in abdominal free flap breast reconstruction
原文传递
导出
摘要 目的评估Coupler静脉吻合器用于乳腺癌游离腹部皮瓣乳房重建的安全性及时效性。方法 2012年7月至2013年12月复旦大学附属肿瘤医院共完成45例游离腹部皮瓣乳房重建,根据吻合静脉血管是否使用Coupler吻合器分为两组:手工吻合组(28例)和Coupler组(17例),比较两组重建手术总时间、皮瓣缺血时间、血管吻合时间,以及因皮瓣循环危象需要手术解救的例数和皮瓣存活率。结果在即刻重建病人中,Coupler组手术总时间较手工吻合组短[(7.1±0.3)h vs.(8.6±0.2)h,P<0.05)];所有病人中,Coupler组皮瓣缺血时间明显缩短[(69.3±3.4)min vs.(81.5±3.7)min,P<0.05)];Coupler组血管吻合时间(包括动、静脉吻合时间)也显著缩短[(47.9±3.3)min vs.(68.5±3.8)min,P<0.05)]。皮瓣循环危象发生率手工吻合组为10.7%(3/28),Coupler组为5.9%(1/17),差异无统计学意义(P>0.05);两组各出现1例部分皮瓣坏死。结论在游离皮瓣乳房重建手术中,与传统吻合技术比较,运用Coupler吻合器进行静脉吻合能够显著缩短手术时间,该技术易于掌握且安全可靠。 Objective To analyze free abdominal flap for breast reconstruction with or without Coupler for venous anastomosis, and investigate its safety and effectiveness. Methods From July 2012 to December 2013~45 cases of free abdominal flap breast reconstruction performed in Fudan University Shanghai Cancer Center were enrolled in the study. Patients were divided into two groups (hand-sewn: 28 cases, Coupler: 17cases). Total surgical time, flap ischemic time, vessels anastomotic time and complications incidence were compared between two groups. Results In immediate reconstruction surgery, Coupler group cost less time for total surgical time [(7.1±0.3)h vs. (8.6±0.2) h,P〈O.01 )]. For all patients, Couplers could not only save flap ischemic time [(85.7±3.7) min vs. (69.3±3.4)min, P〈0.01)], but also save vessels anastomotic time[(47.9±3.3)min vs. (68.5±3.8)min, P〈O.01)]. The rate of acute mierovessel crisis of flap was 10.7% in hand-sewn group, and 5.9% in Coupler group, without statistical significance (P〉0.05). One partial flap necrosis occurred in each group, and no total flap loss occurred. Conclusion Comparing with hand-sewn technique, Coupler provides a safe and reliable method in venous anastomosis, easy to handle and could save surgical time significantly.
出处 《中国实用外科杂志》 CSCD 北大核心 2014年第11期1083-1085,1089,共4页 Chinese Journal of Practical Surgery
关键词 乳腺肿瘤 乳房重建 游离皮瓣 静脉吻合器 显微外科 breast carcinoma breast reconstruction free flap venous coupler microsurgery
  • 相关文献

参考文献11

  • 1Andrades P, Fix RJ, Danilla S, et al. Ischemic complications in pedicle free and muscle sparing transverse rectus Abdominis myocutanemls flaps for breast reconstruction[ J ]. Ann Hast Surg, 2008,60 (5) : 562-567.
  • 2陈颖,陈嘉莹,李琳,陈嘉健,杨犇龙,黄晓燕,陈灿铭,胡震,柳光宇,沈镇宙,邵志敏,俞培荣,吴炅.应用游离腹部皮瓣行118例乳房重建术的单中心报告[J].中国癌症杂志,2013,23(8):576-583. 被引量:12
  • 3李琳,陈颖,陈嘉莹,陈嘉健,杨犇龙,李俊杰,黄晓燕,陈灿铭,胡震,柳光宇,沈镇宙,邵志敏,俞培荣,吴炅.游离腹直肌皮瓣乳房重建102例回顾分析[J].中华显微外科杂志,2013,36(4):383-386. 被引量:5
  • 4Camara O, Herrmann J, Egbe A, et al. Venous coupler for free-flap anastomosis [J]. Anticancer Res, 2009, 29 (7) : 2827-2830.
  • 5Chernichenko N, Ross DA, Shin J, et al. Arterial coupling for mi- crovascular free-tissue transfer [J]. Otolaryngol Head Neck Surg,2008,138(5) :614-618.
  • 6Tran NV, Buchel EW, Conversy PA. Microvascular complica-tions of DIEP Flaps [J]. Plast Reconstr Surg, 2007, 119 (5) : 1397-1405.
  • 7Yap LH, Constantinides J, Butler CE. Venous thrombosis in cou- pled versus sutured microvascular anastomoses [J]. Ann Plast Surg, 2006,57 (6) : 666-669.
  • 8Broer PN, Weichman KE, Tanna N, et al. Venous coupler size in autologous breast reconstruction--does it matter? [J ]. Microsur- gery,2013,33(7) :514-518.
  • 9Jandali S, Wu LC, Vega S J, et al. 1000 consecutive venous anas- tomoses using the microvaseular anastomotie coupler in breast reconstruction[J]. Plast Reconstr Surg,2010, 125(3):792-798.
  • 10Rozen WM, Whitaker IS, Acosta R. Venous Coupler for free-flap anastomosis: outeomes of 1,000 eases [J ]. Anticaneer Res,2010,30(4) : 1293-1294.

二级参考文献41

  • 1Cordeiro PG. Breast reconstruction after surgery for breast cancer. N Engl J Med, 2008, 359:1590-1601.
  • 2Hardwicke JT, Prinsloo DJ . An analysis of 277 consecutive latissimus dorsi breast reconstructions: A focus on capsular contracture. Plast Reconstr Surg, 2011, 128:63-70.
  • 3Prince MD, Suber JS, Aya-Ay ML, et al. Prosthesis salvage in breast reconstruction patients with periprosthetic infection and exposure. Plast Reconstr Surg, 2012, 129:42-48.
  • 4Collins JB, Verheyden CN. Incidence of breast hematoma after placement of breast prostheses. Plast Reconstr Surg, 2012, 129:413-420.
  • 5Arnez ZM, Khan U, Pogorelec D, et al. Rational selection of flaps from the abdomen in breast reconstruction to reduce donor site morbidity. Br J Plast Surg, 1999, 52:351-354.
  • 6Andrades P, Fix R J, Danilla S, et al. Ischemic complications in pedicle, free, and muscle sparing transverse rectus abdominis myocutaneous flaps for breast reconstruction. Ann Plast Surg, 2008, 60:562-567.
  • 7Holm C, Mayr M, Hofter E, et al. Perfusion Zones of the DIEP flap revisited: A clinical study. Plast Reconstr Surg, 2006, 117:57-43.
  • 8Al-Ghazal SK, Fallowfield L, Blarney RW. Comparison of psychological aspects and patient satisfaction following breast conserving surgery, simple mastectomy and breast reconstruction. Eur J Cancer, 2000, 36:1938-1943.
  • 9Shaw WW. Microvascular free flaps. The first decade. Clin Plast Surg, 1983,10:3-20.
  • 10Irons GB, Wood MB, Schmitt EH 3rd. Experience with 1013 consecutive free flaps. Ann Plast Surg, 1987,18:17-23.

共引文献15

同被引文献44

  • 1Fosnot J, Jandali S, Low DW, et al. Closer to an understanding of fate: the role of vascular complications in free flap breast recon- struction[J]. Plast Reconstr Surg, 2011, 128(4): 835-843.
  • 2Andrades P, Fix R J, Danilla S, et al. Ischemic complications in pediele, free, and muscle sparing transverse rectus abdominis myocutaneous flaps for breast reconstruction [ J ]. Ann Plast Surg, 2008, 60(5): 562-567.
  • 3Kubo T, Yano K, Hosokawa K. Management of flaps with com- promised venous outflow in head and neck microsurgical recon- struction[J]. Microsurgery, 2002, 22(8): 391-395.
  • 4Vijan SS, Tran VN. Microvaseular breast reconstruction pedicle thrombosis: how long can we wait? [J]. Microsurgery, 2007, 27 (6): 544-547.
  • 5Bui DT, Cordeiro PG, Hu QY, et al. Free flap reexploration: indi- cations, treatment, and outcomes in 1193 free flaps[J]. Plast Re- constr Surg, 2007, 119(7): 2092-2100.
  • 6Trussler AP, Watson JP, Crisera CA. Late free-flap salvage with catheter-directed thrombolysis [J]. Microsurgery, 2008, 28(4): 217-222.
  • 7Chang EI, Mehrara BJ, Festekjian JH, et al. Vascular complica- tions and mierovascular free flap salvage: the role of thrombolyt- ic agents[J]. Microsurgery, 2011, 31(7): 505-509.
  • 8Chang SY, Huang JJ, Tsao CK, et al. Does ischemia time affect the outcome of free fibula flaps for head and neck reconstruc- tion? A review of 116 cases [J]. Plast Reconstr Surg, 2010, 126 (6): 1988-1995.
  • 9Marre D, Hontanilla B. Increments in ischaemia time induces microvascular complications in the DIEP flap for breast recon- struction[J]. J Plast Reconstr Aesthet Surg, 2013, 66(1): 80-86.
  • 10Carroll WR, Esclamado RM. Ischemia/reperfusion injury in mi- crovascular surgery[J]. Head Neck, 2000, 22(7): 700-713.