期刊文献+

广州蓄能水电厂B厂设备可靠性分析及维护策略探讨

Reliability Analysis and Maintenance Strategies of Equipments in the Plant B of Guangzhou Pumped Storage Power Station
下载PDF
导出
摘要 通过对广州蓄能水电厂B厂投产以来设备运行情况及可靠性指标分析,阐述了影响电厂可靠性指标的主要因素。根据可靠性指标分析结果,建议加强对静止变频启动器(SFC)、主变高压套管、自动化元器件等设备的消缺及升级改造力度,以提升机组可靠性水平。 By analyzing the operations and reliability indicators of equipments in the Plant B of Guangzhou Pumped Storage Power Station since putting into operation, the main factors affecting plant reliability are studied. Based on reliability analysis results, it is suggested to strengthen the upgrading of Static Frequency Converters (SFCs), high voltage casings of main transformers and automatic components to eliminate the defects and for improving the reliability of units.
作者 柳艳红
机构地区 广州蓄能水电厂
出处 《水力发电》 北大核心 2014年第11期97-100,共4页 Water Power
关键词 可靠性 非计划停运率 等效可用系数 广州蓄能水电厂 reliability unplanned outage rate equivalent availability factor Guangzhou Pumped Storage Power Station
  • 相关文献

参考文献4

二级参考文献6

  • 1电力可靠性管理中心,2012年度全国电力可靠性趋势分析及同业对标报告[R].电力可靠性管理报告,2013.
  • 2包叙定,张国宝,陆燕逊,等.中国电机工业发展史[M].北京:机械工业出版社,2011:258-264.
  • 3吕峰.天荒坪抽水蓄能电站设备运行统计与可靠性分析[J].华电力,2011,39(10):1671-1675.
  • 4DL/T 836-2003.供电系统用户供电可靠性评价规程[S],2003.
  • 5DL/T 793-2001.发电设备可靠性评价规程[S],2001.
  • 6王利亚.浅谈抽水蓄能机组可靠性管理[J].广东电力,2003,16(5):73-75. 被引量:4