摘要
通过开展变负荷机组的热化学实验,监督不同负荷工况下的汽水品质,确定较为经济的锅炉连续排污流量,对产生的效益进行了分析和计算。
Through thermo-chemical experiment of the load-varying generating unit to monitor the steam and water quality under different loads, the economical flowrate of contin-uous waste water drainage was determined. Benefit resulted was also analyzed and calculated.
出处
《冶金动力》
2014年第9期50-52,共3页
Metallurgical Power
关键词
变负荷
连排
效益
load varying
continuous waste water drainage
benefit