摘要 心内膜导线相关的三尖瓣返流的发生率为11%-39%。 其发生机制第一,导线的机械作用:包括淤导线嵌顿于瓣叶之前;于导线与瓣叶粘连;盂导线与腱索缠结;榆瓣叶穿孔或撕裂;虞瓣环扩张;第二,右室心尖部起搏改变了心脏的收缩顺序。 轻中度三尖瓣返流多无明显症状,重度返流常表现为右心衰竭。 治疗有针对症状的药物治疗,以及病因的导线拔除,外科瓣膜成形与置换。
出处 《中国心脏起搏与心电生理杂志》 2014年第5期443-445,共3页 Chinese Journal of Cardiac Pacing and Electrophysiology
  • 相关文献

参考文献21

  • 1Leibowitz DW, Rosenheck S, Pollak A, et al. Transvenous pace- maker leads do not worsen tricuspid regurgitation: a prospective ech- ocardiographic study[ J]. Cardiology, 2000,93 ( 1-2 ) :74.
  • 2Seo Y, Ishizu T, Nakajima H, et al. Clinical utility of 3-dimension- al echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads[ J]. C irc J, 2008,72 (9) :1 465.
  • 3Paniagua D, Aldrich HR, Lieberman EH, et al. Increased preva- lence of significant tricuspid regurgitation in patients with trans- venous pacemakers leads[J]. Am J Cardiol, 1998,82(9) :1 130.
  • 4Kim JB, Spevack DM, Tunick PA, et al. The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study [ J ]. J Am Soc Echocardiogr, 2008,21 (3) :284.
  • 5Klutstein M, Balkin J, Butnaru A, et al. Tricuspid incompetence following permanent pacemaker implantation [ J ]. Pacing Clin Elec- trophysiol, 2009,32 Suppl 1 : S135.
  • 6任崇雷,王瑶,王嵘,李伯君,耿仁义,高长青.起搏器植入术后对三尖瓣反流的远期影响[J].中华医学杂志,2012,92(30):2118-2122. 被引量:13
  • 7Lin G, Nishimura RA, Connolly HM, et al. Severe symptomatic tri- cuspid valve regurgitation due to permanent pacemaker or implant- able cardioverter-defibrillator leads [ J ]. J Am Coll Cardiol, 2005, 45(10) :1 672.
  • 8Novak M, Dvorak P, Kamaryt P, et al. Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes [ J ]. Europace, 2009,11(11) :1 510.
  • 9Pfannmueller B, Hirnle G, Seeburger J, et al. Tricuspid valve re- pair in the presence of a permanent ventricular pacemaker lead [ J ]. Eur J Cardiothorac Surg, 2011,39 (5) :657.
  • 10Vaturi M, Kusniec J, Shapira Y, et al. Right ventricular pacing in- creases tricuspid regurgitation grade regardless of the mechanical in- terference to the valve by the electrode [ J ]. Eur J Echocardiogr, 2010,11(6) :550.

二级参考文献29

  • 1方平,吴宗贵.VVI起搏器工作停止后心房扩大和房室瓣反流的逆转[J].中国介入心脏病学杂志,1997,5(1):31-33. 被引量:1
  • 2Rogers JH, Boiling SF. The tricuspid valve current perspective and evolving management of tricuspid regurgitation. Circulation, 2009,119:2718-2725.
  • 3沈法荣,郑良荣,徐耕.超声心动图与心脏起搏//叶萌.现代心脏起搏治疗学.上海:上海科学技术出版社,2004:466-471.
  • 4Zoghbi WA, Enriquez-Sarano M, Foster E, et al. Recommendations for evaluation of the severity of native valvular regurgitation with two dimensional and Doppler echocardiography. J Am Soc Echocardiogr, 2003,16:777-802.
  • 5Cairns BBK, Klaster FE, Bristow JD, et al. Problems in the hemodynamie diagnosis of tricuspid insufficiency. Am Heart J, 1968,75 : 174-179.
  • 6Jacobs P, Vandenbossche JL, de Marneffe M, et al. Pseudo tricuspid regurgitation in ventricular pacing. Am Heart J, 1985, 110:886-888.
  • 7Paniagu D, Aldrich H, Lieberman E, et al. Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads. Am J Cardiol, 1998, 82 : 1130-1132.
  • 8Kim JB, Spevack DM, Tunick PA~ et al. The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study. J Am Soc Eehocardiogr, 2008,21:284-287.
  • 9Klutstein M, Balkin J, Butnaru A, et al. Tricuspid incompetence following permanent pacemaker implantation. PACE Pacing Clin Electrophysiol, 2009,32 :S135-S137.
  • 10Leibowitz DW, Rosenheck S, Pollak A, et al. Transvenous pacemaker leads do not women tricuspid regurgitation : a prospective echocardiographic study. Cardiology, 2000,93:74-77.

共引文献20

同被引文献29

  • 1Kirkfeldt RE, Johansen JB, Nohr EA, et al. Complications af- ter cardiac implantable electronic device implantations an anal- ysis of a complete, nationwide cohort in Denmark[J]. Eur Heart J,2014,35(18) :1 186.
  • 2Udo EO, Zuithoff NPA, van Hemel NM, et al. Incidence and predictors of short- and long-term complications in pacemaker therapy : The FOLLOWPACE study[J]. Heart Rhythm,2012, 9(5) :728.
  • 3Ann HW, Ahn JY, Jeon YD, et al. Incidence of and risk fac- tors for infectious complications in patients with cardiac device implantation[J]. Int J infect Dis, 2015,36(2015):9.
  • 4Wilkoff BL. How to treat and identify device infections[J]. Heart Rhythm, 2007,4(11) : 1 467.
  • 5Johansen JB, Jrgensen OD, Mailer M, et al. Infection after pacemaker implantation: infection rates and risk factors associ- ated with infection in a population-based cohort study of 46299 consecutive patients[J]. Eur Heart J, 2011,32(8):991.
  • 6Poole JE, Gleva MJ, Mela T, et al. Complication rates associ- ated with pacemaker or implantable eardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry[J]. Circulation, 2010,122(16) : 1 553.
  • 7Aizawa Y, Negishi M, Kashimura S, et al. Predictive factors of lead failure in patients implanted with cardiac device[J]. Int J Cardiol, 2015,199(2015) :277.
  • 8Spickler JW, Rasor NS, Kezdi P, et at. Totally self-contained intracardiac pacemaker[J]. J Electrocardiol, 1970, 3 ( 3 -- 4) : 325.
  • 9Reddy VY, Knops RE, Sperzel J, et al. Permanent leadIess cardiac pacing: results of the LEADLESS trial[J]. Circulation, 2014,129(14) :1 466.
  • 10Neuzil P, Reddy VY. Leadless cardiac pacemakers:pacing para- digm change[J]. Curr Cardiol Rep, 2015,17(8)168.