期刊文献+

Development of Instantaneous Hot Water Dispenser Based on Water Source Heat Pump

Development of Instantaneous Hot Water Dispenser Based on Water Source Heat Pump
下载PDF
导出
摘要 Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi-use heat pump) to achieve higher efficiency than traditional systems. The MMHP system connects multiple heat sources such as solar heat, the ground, and air and multiple heat uses such as cooling, heating, and a hot water dispenser with a water loop. Each type of heat use side can utilize heat efficiently. However, there is a distinct lack of highly efficient hot water dispensers available. Therefore, we developed the IHWD WS (instantaneous hot water dispenser based on a water source) heat pump. In this study, we developed a prototype of the IHWD WS heat pump. The coefficient of performance of the IHWD WS heat pump was 5.2-8.5 throughout a year. When it is improved, COP (coefficient of performance) is expected to be 9.3-9.9.
出处 《Journal of Energy and Power Engineering》 2014年第10期1703-1711,共9页 能源与动力工程(美国大卫英文)
关键词 Heat pumps hot water EFFICIENCY COP ground source. 水源热泵 饮水机 瞬间 性能系数 P系统 分配器 自然能源 能源消耗
  • 相关文献

参考文献8

  • 1Ministry of Economy, Trade and Industry. 2013. Agency for Natural Resources and Energy. FY 2013 Annual energy report.
  • 2Omer, A. M. 2008. "Energy, Environment and Sustainable Development." Renewable and Sustainable Energy Reviews 12 (9): 2265-300.
  • 3Li, X., Chen, Z., and Zhao, J. 2006. "Simulation and Experiment on the Thermal Performance of U-vertical Ground Coupled Heat Exchanger." Applied Thermal Engineering 26 (14-15): 1564-71.
  • 4Ooka, R., Hino, T., Sato, H., Miyauchi, K., Shin, D., and Harada, Y. 2011. "Development of Multi-source and Multi-use Heat Pump System." Presented at 2011 the 10th International Energy Agency Heat Pump Conference, Tokyo, Japan.
  • 5Hikawa, T. 2014. "An Overview of Recent Heat Pump Trend in Asia/Oceania Region, Regional Report Asia." Presented at the 1 lth International Energy Agency Heat Pump Conference, Montreal, USA.
  • 6Yokoyama, R., Shimizu, T., Takemura, K., and Ito, K. 2005. "Performance Analysis of a Hot Water Supply System with a CO2 Heat Pump by Numerical Simulation (lst Report, Modeling and Analysis of Heat Pump)." JSME International Journal Series B Fluids and Thermal Engineering 48 (3): 540-7.
  • 7Hamada, Y., Murakawa, S., Amazawa, K., Kitayama, H., Nabeshima, M., and Takata, H. 2011. "Study on the Performance Evaluation of Domestic Hot Water Supply System using Storage Tank (Experiments and Analysis on the Operation Control Modes of CO2 Heat Pump Water Heater)." The Society of Heating, Air-Conditioning Sanitary Engineers of Japan Scientific Paper 173: 1-9.
  • 8Hino, T., Ooka, R., Ono, K., Yoshida, S., and Kodama, K. 2013. "Energy Conservation Possibilities of Domestic Hot Water Supply by Water-Source Heat Pumps." Presented at 2013 the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan Annual Meeting, Nagano, Japan.