期刊文献+

串联式主机上游冰蓄冷系统乙二醇泵变频的节能效果分析 被引量:4

Energy saving effect analysis of frequency conversion glycol pump of series upstream-cooler ice-storage systems
下载PDF
导出
摘要 分析了乙二醇泵变频与冷水泵变频的区别,对北京某办公楼冰蓄冷系统乙二醇泵变频和工频运行时的全年运行费用进行了计算。结果表明,当控制系统运行在最佳状况时,相对工频系统,乙二醇泵变频系统可以节省电费21.7%,但同时增加了控制系统的复杂性;乙二醇泵变频控制结合制冷机旁通可以更好地实现节能,尤其是对于体量较大、分期建设的区域供冷项目。 Analyses the difference between glycol pump frequency conversion and chilled water pump frequency conversion,and calculates the annual operating cost of the ice-storage system with frequency conversion glycol pump or power frequency pump of an office building in Beijing,respectively.The results show that the annual electricity consumption of the frequency conversion glycol pump is less than that of power frequency pump by 21.7%,but the control system is more complex.The system combining frequency conversion glycol pump with refrigerating machine bypass can achieve better energy saving effects,especially for large volume district cooling projects with stage construction.
作者 陈亮
出处 《暖通空调》 北大核心 2014年第10期67-71,78,共6页 Heating Ventilating & Air Conditioning
关键词 冰蓄冷系统 乙二醇泵 变频 制冷机旁通 节能效果 ice-storage system glycol pump frequency conversion refrigerating machine bypass energy saving effect
  • 相关文献

参考文献3

二级参考文献17

  • 1姚国梁.空调变频水泵节能问题探讨[J].暖通空调,2004,34(6):32-34. 被引量:37
  • 2武文杰,黄普.循环水泵的配置及变频调速的能耗分析[J].煤气与热力,2004,24(7):388-390. 被引量:10
  • 3彦启森.冰蓄冷系统设计[M].清华大学,1996,4..
  • 4张永铨.中国大陆蓄冰技术应用的新进展.第4届海峡两岸制冷空调技术交流会大陆部分论文集[M].台北,1999..
  • 5赵庆珠 骆维军 等.蓄冰系统现场测试研究与问题探讨.中国制冷学会新世纪中国蓄冷空调技术研讨会论文集[M].杭州,1999..
  • 6叶晖 秦慧敏.冰蓄冷技术应用于商办大楼的经济效果分析.1996年全国暖通空调制冷学术年会论文集[M].,1996..
  • 7赵庆珠 骆维军 等.唐山百货大楼的蓄冰空调改造.中国制冷学会新世纪中国蓄冷空调技术研讨会论文集[M].杭州,1999..
  • 8张雁.蓄冰空调系统动态仿真软件的开发研究:硕士学位论文[M].北京:清华大学,1998..
  • 9殷平.空调设计-冰蓄冷工程实例集[M].长沙:湖南科学技术出版社,1998,3
  • 10陆耀庆.实用供热空调设计手册[M].北京:中国建筑工业出版社,1995..

共引文献17

同被引文献11

引证文献4

二级引证文献4