摘要 在发电站系统中,常因励磁变压器故障,很难满足海外电站高运行小时数的要求。通过研究大型水轮发电机组励磁变压器温升曲线,提出制造厂家一些问题,并采取一定措施,解决了在水轮发电机在高运行小时数情况下,检修和维护励磁变压器的方法。方法简易、方便,并且试验结果有效,对其它海外项目有借鉴意义。 The power station system, often due to excita- tion transformer failure is difficult to meet the requirements of o- verseas-power plant operating hours. By studying the tempera- ture rise curve of excitation transformer on the large hydroelec- tric overseas, this paper submits some of the manufacturering problems, takes certain measures to check & maintain the exci- tation transformer when the hydraulic generator is in the case of the high number of operating hours. The method is simple, con- venient & effective in test result. For other projects overseas, the above mentioned methods can be taken as reference.
作者 陈伟
出处 《电力学报》 2014年第5期410-415,共6页 Journal of Electric Power
关键词 励磁变压器 老化 温升曲线 温度限制 exciting transformer aging temperaturerise curve temperature restraint
  • 相关文献

参考文献6

  • 1周代红,田力,杜焕章.三峡电厂发电机组常规检修流程[J].水电自动化与大坝监测,2008,32(6):28-31. 被引量:5
  • 2杜文忠.水力机组测试技术[M].北京:水利水电出版社,1994.
  • 3IEEE Industry Application Society, ANSI/IEEE std 120-1989 and IEEE Master Test Guide for Electrical Measurements in Power Circuits[S]. 1993.
  • 4中华人民共和国国家经济贸易委员会.DIdT507-1993水轮发电机起动试验规程[S].北京:中国标准出版社,1993.
  • 5中华人民共和国建设部.GB50150—2006.电气装置安装工程电气设备交接试验标准[S].北京:中国计划出版社,2006.
  • 6陈伟,夏朋辉,何邕.印尼小电网过激磁保护设置的分析及处理[J].电力学报,2014,29(1):14-19. 被引量:6