电压波动和闪变对整流桥后电解电容器的影响 被引量:1

The impact of voltage fluctuation and flicker on electrolytic capacitor after bridge rectifier
下载PDF
导出
摘要 电网电压存在波动和闪变,使整流桥后电解电容器的纹波电流明显增加,导致其损耗增加和使用寿命缩短。为了分析该现象的成因和机制,利用三角函数模型定性分析电网电压波动和闪变引起电解电容器纹波电流的变化情况,同时推导验证了其有效值变大的现象。同时还介绍了电容器纹波电流的测试方法,并采用具有傅里叶分析功能的示波器对实际样机的纹波电流进行测试分析,获得了支持理论分析的实验数据和结果。 Voltage fluctuation and flicker existing in electrified wire netting make ripple current of electrolytic capacitors increasing after bridge rectifier and result in loss increased and life reduced.In order to analyze the cause and mechanism of this phenomenon,this paper qualitatively analyzes the variation of electrolytic capacitor ripple current caused by voltage fluctuation and flicker through trigonometric model.And it is also derived about current RMS larger phenomenon.Finally,the test method of capacitor ripple current is described.Measurement experiment on a prototype using an oscilloscope which can make current waveform Fourier decomposition,is tested and analyzed in the paper,and obtaining experimental data supports theoretical analysis.
出处 《电子技术应用》 北大核心 2014年第11期64-67,共4页 Application of Electronic Technique
基金 国家863重大专项(2012AA03A301 2013AA030601) 国家自然科学基金(61101169 61106053) 福建省2014年省属高校科研课题JK类重点项目资助
关键词 电压波动 闪变 电解电容器 纹波电流 voltage fluctuation flicker electrolytic capacitor ripple current
  • 相关文献

参考文献8

  • 1徐立刚,陈乾宏,朱祥,封骏.整流后滤波用电解电容的选择[J].电源世界,2008(10):70-73. 被引量:5
  • 2AMARAL A, CARDOSO A.An economic offline technique for estimating the equivalent circuit of aluminum electrolytic capacitors [ J ]. IEEE Trans. I nstrum. Meas, 2008,57 (12) : 2697-2710.
  • 3REDL R.Electromagnetic environmental impact of power electronics equipment [J].Proc .IEEE, 2001,89(6) : 926-938.
  • 4林海雪.电能质量国家标准系列讲座 第4讲 电压波动和闪变标准[J].建筑电气,2011,30(8):12-16. 被引量:4
  • 5CAI R,COBBEN J, MYRZIK J,et al.Flicker responses of different lamp types [J ].lET Generation, Transmiss. Distrib, 2009,3(9) : 816-824.
  • 6Electromagnetic compatibility(EMC)-part 4-15 :Testing and measurement techniques-flickermeter-function and design specifications, IEC 61000-4-15, edition 2.0(2010-08) Std[Z].2010.
  • 7曾兴雯.高频电子线路[M].北京:高等教育出版社,2005.
  • 8GANDOY J D, CASTRO C, MARTINEZ M.Line input ac- to-dc conversion and filter capacitor design[J].IEEE Trans. Ind.Appl, 2003,39(4) : 1169-1176.

二级参考文献6

  • 1中国电力科学研究院,等起草.GB/T12326-2008电能质量电压波动和闪变[S].北京:中国标准出版社.2009.
  • 2国家电力公司武汉高压研究所,等负责起草.GB/Z17625.5-2000idtIEC61000-3-7:1996电磁兼容限值中、高压电力系统中波动负荷发射限值的评估[s].北京:中国标准出版社,2000.
  • 3British Standard Institution. BS EN 50160:2007 Voltage characteristics of electricity supplied by public distribution system [S]. 2007.
  • 4International Electrotechnical Commission. IEC 61000 - 4 - 30 Electromagnetic compatibility (EMC) -- Part 4 - 30: Testing and measurement techniques -- Power quality measurement methods[S ]. Geneva.
  • 5IEC61000-4-15电磁兼容试验和测量技术闪变仪功能和设计规范[S].
  • 6International Electrotechnical Commission. IEC 61000-3-7 : 2008 Electromagnetic compatibility (EMC) --Part 3 -7: Limits--Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems [S]. Geneva.