期刊文献+

颅内压检测技术研究进展 被引量:1

Advances of non-invasive detection of intracranial pressure
原文传递
导出
摘要 近年来,随着颅内压(ICP)检测精度的提高,其在临床上的应用也越来越多.多种检测技术被运用于临床,可分为侵入式硬脑膜外导管法、蛛网膜下腔螺栓法、脑室导管法、光纤探头检测、微型芯片和非侵入式诱发耳声刺激法、经眼检测法、经颅多普勒法、影像学方法及磁感应检测法.就ICP检测生理基础,常见ICP检测技术,特别对非侵入式ICP检测方法进行了综述,评价了ICP检测方法的优缺点,并展望了非侵入式ICP检测技术的发展. In recent years,with the increasement of intracranial pressure detection accuracy,the use of intracranial pressure detection in clinic become more common.Various of technologies are used in clinic that can be divided into invasive methods,such as epidural catheter,subarachnoid bolt,intraventricular catheter,fiberoptic catheter and micro-sensors transducer,and non-invasive methods,such as evoked otoacoustic emissions,transocular method,transcranial doppler,imaging method and magnetic induction method.This paper reviews the physiological basis of intracranial pressure detection and common intracranial pressure detection techniques,especially on noninvasive intracranial pressure detection methods.Advantages and disadvantages of different intracranial pressure detection methods are listed,and an outlook of the development of non-invasive intracranial pressure detection technology are made.
出处 《国际生物医学工程杂志》 CAS 2014年第5期307-310,共4页 International Journal of Biomedical Engineering
基金 国家自然科学基金资助项目(61072006)
关键词 颅内压 监测 侵入 非侵入 Intracranial pressure Detection Invasive Non-invasive
  • 相关文献

参考文献40

  • 1吴承远,刘玉光.临床神经外科学[M].北京:人民卫生出版社,2007.322-323.
  • 2Miller JD, Becker DP, Ward JD, et al. Significance of intracranial hypertension in severe head inju:[J]. J Neurosurg, 1977, 47(4): 503- 516.
  • 3Chesnut RM, Petroni G, Rondina C. Intracranial-pressure monitoring in traumatic brain injury[J]. N Engl J Med, 2013, 368(18): 1751- 1752.
  • 4Kirkman MA, Smith M. Intracranial pressure monitoring, cerebral perfusion pressure estimation, and ICP/CPP-guided therapy: a standard of care or optional extra after brain injury?[J]. Br J Anaesth, 2014, 112(1): 35-46.
  • 5Wostyn P. De Groot V, Van Dam D, et al. The role of low intracranial pressure in the development of glaucoma in patients with Alzheimer's disease[J]. Prog Retin Eye Res, 2014, 39: 107-108.
  • 6Monro A. Observations on the Structure and Functions of the Nervous System[M]. London : Edinburgh, 1783.
  • 7Foley J. Benign forms of intracrania[ hypertension; toxic and otitic hydrocephalus[J]. Brain, 1955, 78(1): 1-41.
  • 8Lundberg N. Continuous recording and control of ventricular fluid pressure in neurosm'gical practice[J]. Acta Psychiatr Seand Suppl, 1960, 36(149): 1-193.
  • 9Mokfi B. The Monro-Kellie hypothesis: applications in CSF volume depletion[J]. Neurology. 2001, 56(12): 1746-1748.
  • 10Avezaat C J, van Eijndhoven J H. Wyper DJ. Cerebrospinal fluid pulse pressure and intracrania olume-pressure relationships[J]. J Neurol Neurosurg Psychiatry. 1979, 42(8): 687-700.

二级参考文献41

  • 1秦明新,焦李成,李世俊,王聪,吕华,董秀珍.MIT单通道测量的电磁关系及脑组织电导率测量参数计算[J].第四军医大学学报,2004,25(21):2007-2010. 被引量:11
  • 2穆飞航,王健琪,叶勇,荆西京,焦腾,张杨,谢昇.雷达式生命探测仪后端系统的研制[J].医疗卫生装备,2005,26(3):20-21. 被引量:8
  • 3QINMing-xing,JIAOLi-cheng,WANGCong,LIShi-jun,DONGXiu-zhen,LUHua.A Single Channel Measurement System For Brain MIT[J].Chinese Journal of Biomedical Engineering(English Edition),2004,13(3):93-100. 被引量:2
  • 4何园丁,何为,徐征,张占龙.开放式磁感应成像系统设计[J].医疗卫生装备,2007,28(5):34-36. 被引量:2
  • 5Johannes Netz, Ewald Fornert, Sabine Elaagemannf. Contactless impedance measurement by magnetic induction-a possible method for investigation of brain impedance[J]. Physiol. Meas., 1993,14:463~471.
  • 6Griffiths H, Stewart WR, Gough W. Magnetic induction tomography-A measuring system for biological tissues[J]. Ann N Y Acad Sci., 1999,873:335~345.
  • 7Griffiths H. Magnetic induction tomography [J]. measurement science and technology, 2001,12:1126~1131.
  • 8Morris A, Griffiths H, Gough W. A numerical model for magnetic induction tomographic measurements in biological tissues[J]. Physiol. Meas., 2001,22:113~119.
  • 9S Watsonl, R J Williams, H Griffiths, W Gough, A Morris. Magnetic induction tomography: phase versus vector-voltmeter measurement techniques[J]. Physiol. Meas., 2003,24:555~564.
  • 10Steffen M, Alek sandrowicz A, Leonhardt S. Mobile noncontact monitoring of heart and lung activity[J]. IEEE Trans Circ Syst, 2007, 1(4): 250-257.

共引文献48

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部