摘要 以高速动车组项目为背景,研究和实现了辅助变流器并联系统的控制策略。利用PQ下垂法,通过计算各辅助变流器的输出有功功率和无功功率,对其输出电压和频率进行下垂特性控制,以实现无互联线的辅助变流器并联。从高速动车组辅助变流器并联满功率地面组合试验结果来看,该并联系统运行稳定,动态响应快,均流效果良好。 The control strategy of parallel inverters was analyzed and implemented with the background of high-speed EMU program. By calculating positive power and negative power, output voltage and frequency of auxiliary inverters were controlled with the PQ droop method to implement auxiliary inverters in parallel with no control interconnection. Result of the full-power ground combination experiment to high- speed EMU parallel inverters show that the parallel system has stable operation, fast transient response and good current-sharing.
出处 《大功率变流技术》 2014年第5期17-23,共7页 HIGH POWER CONVERTER TECHNOLOGY
关键词 辅助变流器 并联控制 PQ下垂特性 三相软件锁相环 auxiliary inverter parallel control PQ droop characteristic three-phase software phase-locked loop
  • 相关文献

参考文献3

二级参考文献19

  • 1成晟,邵英.逆变器并联控制技术研究[J].舰船电子工程,2008,28(7):99-101. 被引量:4
  • 2肖岚,陈良亮,李睿,严仰光.基于有功和无功环流控制的DC-AC逆变器并联系统分析与实现[J].电工技术学报,2005,20(10):7-12. 被引量:19
  • 3张纯江,陈桂涛,祖峰,邬伟扬.一种全数字化互动跟踪式单相逆变电源并联均流控制策略[J].中国电机工程学报,2006,26(10):63-66. 被引量:22
  • 4[4]Changjiang Zhan, Fitzer C, Ramachandaramurthy, et al. Software Phase-Locked Loop Applied to Dynamic Voltage Restorer (DVR) [J ]. IEEE Power Engineering Society Winter 2001, 3:1033-1038.
  • 5[6]Kanra V, Blasko V. Operation of a Phase Locked Loop System under Distorted Utility Conditions [J]. IEEE Transactions on Industry Applications, 1997, 33(1) :58-63.
  • 6[1]H.Yamashita.Uninterruptible power supply systems in NTT[C].IEEE-INTELEC,1990
  • 7[2]U.De Pra,D.Baert,H.Kuyken.Analysis of the degree of reliability of a redundant modular inverter structure[C].IEEE-INTELEC,1998
  • 8[3]Chen J.F.et al.Combination Voltage-Controlled and Current-Congtrolled PWM Inverters for UPS Parallel Operation[J].IEEE,Transaction on ElcctroniCS,1995,10 (5):547~558
  • 9[11]M.Ramanoorthy.Application of Digital Computers to Power System Protection[J].T.Inst.Eng.(India),1977,52:235~238
  • 10BYUN Y B.Parallel operation of three-phase UPS inverters by wireless load sharing control[C]//INTELEC-2000.Hyatt Regency Phoenix.2000:526-532.

共引文献26

同被引文献18

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部