摘要
通过反渗透海水淡化中试试验分析恒定膜通量条件下,操作压力和脱盐率的温度特性。对比软件模拟数据和现场中试试验数据,验证了恒定通量条件下,操作压力随温度升高逐渐降低,脱盐率随温度升高逐渐降低。
Based on the reverse osmosis sea water desalination pilot scale test,the operation pressure temperature characteristics and the desalination rate temperature characteristics of the sea water desalination system under condition of constant membrane flux were analyzed. Comparing the software simulation data and the site pilot scale test data,it was verified that under condition of constant membrane flux,when the temperature is increasing,the operation pressure decreases gradually,and the desalination rate decreases gradually too.
出处
《华电技术》
CAS
2014年第10期1-4,77,共4页
HUADIAN TECHNOLOGY
关键词
海水淡化
反渗透
恒通量
操作压力
脱盐率
sea water desalination
reverse osmosis
constant flux
operation pressure
desalination rate